25
The SLATE106 device software file is embedded into SMH300 firmware file.
So the paired SLATE106 devices upgrade their software release file automatically as soon as they are connecting to
the SMH300.
Pre-requisite:
Check that the pairing is effective
Inactivate the ‘Slate pairing’ mode of the SMH300 (back to nominal mode)
8.2.8
SLATE106 device or SMH300 device replacement
In case of you must replace a SLATE106 device which was paired to a SMH300 device:
Unpair the old SLATE106 from the SMH300 device
Pair the new SLATE106 device to the SMH300 device by assigning the same identifier as the previous
SLATE106 device
In case of you must replace a SMH300 device which was paired to several SLATE106 devices:
Configure the new SMH300 device,
Pair all the SLATE106 devices of the previous SMH300 device.
o
If PIN code was used, you must enter the appropriate PIN code
Note: If you don’t know the PIN code, to work around, you can connect the one after the other to all SLATE106 devices paired to the