![Inline IN1401 Operation Manual Download Page 18](http://html1.mh-extra.com/html/inline/in1401/in1401_operation-manual_2061955018.webp)
17
© 2002 - INLINE, Inc.
IN1401 Operation Manual - v1.5 7/12/02 11:18 AM
Key Concept
IN1401 SERIAL COMMANDS
COMMAND
DESCRIPTION
ACI3
set baud rate to 1200
ACI4
set baud rate to 2400
ACI5
set baud rate to 4800
ACI6
set baud rate to 9600**
ACI7
set baud rate to 19,200
ACI8
set baud rate to 38,400
ACI9
set baud rate to 57,600
ACI?
return baud rate
AL+
increase active lines
AL-
decrease active lines
AL@
set active lines to
normal**
♦
ALxxx
set active lines to absolute
value
♦
AL?
return active lines
AP+
increase active pixels by 2
AP-
decrease active pixels by 2
AP@
set active pixels to
normal**
♦
APxxx
set active pixels to absolute
value
♦
AP?
return active pixels
BH+
increase input horizontal
blanking
BH-
decrease input horizontal
blanking
BH@
set input horizontal
blanking to normal**
♦
BHxxx
set input horizontal
blanking to absolute
value
♦
BH?
return input horizontal
blanking
BLU+
increase blue gain
BLU-
decrease blue gain
BLU@
set blue gain to
normal**(128)
COMMAND
DESCRIPTION
BLUxxx
set blue gain to absolute
value (0-255)
BLU?
Return blue gain
BLS0
blue screen ON
BLS1
blue screen OFF
BV+
increase input vertical
blanking
BV-
decrease input vertical
blanking
BV@
set input vertical blanking
to normal**
♦
BVxxx
set input vertical blanking
to absolute value
♦
BV?
return input vertical
blanking
BRG+
increase brightness
BRG-
decrease brightness
BRG@
set brightness to normal**
(128)
BRGxxx
set brightness to absolute
value (000-255)
BRG?
return current brightness
CMDCD0
set delimiters to brackets [
]**
CMDCD1
set delimiters to braces { }
CMDCD2
set delimiters to
parentheses ( )
CMDCD3
set delimiters to less and
greater < >
CMDCD4
set delimiters to slashes \ /
CMDCD5
set delimiters to signs !#
CMDCD? Return
delimiters
CON+
increase contrast
CON-
decrease contrast
CON@
set contrast to normal**
(128)
CONxxx
set contrast to absolute
value (000-255)
When controlling multiple units, the Controller Receiver Terminal must con-
nect to only one IN1401 Transmit Terminal. Multiple IN1401 Transit Lines
may not be connected together; otherwise signal contention from multiple
units will result. Therefore, “receive” information is only available from one
IN1401 in this configuration. Each unit must be set to different delimiters.