37
initio
®
Upgrading/Changing Driver on an Existing IntraNetWare
Server
1
To begin the you will need to change the directory to the location of the server and
initialize the network server, e.g.,
Type
CD \ NWSERVER <ENTER>
Type
SERVER
<ENTER>
2
At the NetWare prompt, Type
LOAD INSTALL
<ENTER>.
3
Select
Driver Options
from the window by highlighting it using the UP or DOWN
ARROW keys, press
<ENTER>
Select
Configure disk and storage device drivers
from the window by high-
lighting it using the UP or DOWN ARROW keys, press
<ENTER>
4
Highlight
Deselect a selected driver
and press
<ENTER>
5
Highlight the driver you wish to replace/upgrade and press
<ENTER>
Repeat steps 4 and 5 for each instance of the driver
6
When all of the drivers you wish to upgrade/replace have been removed highlight
Select an additional driver
and press
<ENTER>
7
Press
<INS>
followed by
<F3>
8
Enter the location path of the drivers
A:\
9
Select the driver you wish to load
INI9100.HAM
or
INI910U.DSK
and press
<ENTER>
If the
HAM
driver(s) are being used proceed to step 10. If you use the
DSK
driver
the upgrade is complete and you may exit the install utility.
10
Highlight
Select and modify parameters
and press
<ENTER>
Enter the slot number and press
<F10>
to continue
11
Highlight
Save parameters and continue
and press
<ENTER>
12
Repeat steps 6 through 11 for each additional adapter installed
Novell NetWare Driver Installation