An event is a condition recognized by the SmartLinkAdv; each event
is characterized by an activation (when an event occurs) and a
restoral (when the event ends).
The following table shows the events the control panel recognizes,
the number of events for each type, the trigger and restoral method
of each event and whether the event is a pulse event (pulse events
restore automatically soon after activation).
Table 7-3:
Event type
Name
Occurs when...
Restores when ...
Number of
events
Pulse
events
Zone alarm
A zone generates an alarm
A zone restores
One event for
each zone
no
Terminal tamper
A terminal detects tamper
(short-circuit or wire cutting)
A terminal restores
One event for
each terminal
no
Generic alarm
At least one zone is generating
an alarm
All the zones have reset
1
no
Real-time zone
The electrical status of a zone
switches from standby to alarm
The electrical status of a zone
switches from alarm to
standby
One event for
each zone
no
The event is independent of the zone type and the armed/
disarmed status.
Not ready to arm A zone is not in standby status
All the zones are in standby
status.
1
no
Away arming
request
A request is made to arm in
Away mode
A request is made to disarm
the partition
1
Yes
Stay arming
request
A request is made to arm in
Stay or in Instant mode
A request is made to disarm
the partition
1
Yes
Arming effective
SmartLinkAdv is effectively
armed in Away mode
SmartLinkAdv is effectively
disarmed
1
no
Stay arming
effective
SmartLinkAdv is effectively
armed in Stay or Instant mode
SmartLinkAdv is effectively
disarmed
1
no
Memory reset
Memory reset is requested
1
Yes
Exit time
The exit time is running
The exit time expires
1
no
Entry time
The entry time is running
The entry time expires
1
no
Valid user-code
recognized
A PIN entered at a keypad is
recognized as valid
One event for
each code
Yes
Open-panel
tamper
The SmartLinkAdv frontplate is
removed
The SmartLinkAdv frontplate
is closed
1
no
Low battery
The backup-battery voltage is
below 10.7V
The backup-battery voltage is
over 11.74V
1
no
Battery fault
The backup battery is low
The backup battery is charged
1
no
Battery not
connected
Battery not detected or
disconnected
Battery connected
1