104
TK 56171-2-OP-EN
•
If the unit is currently operating in Electric Mode, the DIESEL MODE
selection will appear in the Main Menu.
Electric Mode Operation
If a unit equipped with the electric standby SmartPower option is running in
Diesel Mode, the Diesel to Electric Auto-Switch feature is set NO and the unit
is connected to a source of standby power, this feature allows the operator
to manually select electric mode operation. This feature does not appear if
the electric standby SmartPower option is not installed or if the Diesel to
Electric Auto-Switch feature is set YES.
Diesel Mode Operation
If a unit equipped with the electric standby SmartPower option is running in
Electric Mode and the Electric to Diesel Auto-Switch feature is set NO, this
feature allows the operator to manually select diesel mode operation. This
feature does not appear if the electric standby SmartPower option is not
installed or if the Electric to Diesel Auto-Switch feature is set YES.
Switching from Diesel to Electric
If the unit is running in Diesel Mode and the Diesel to Electric Auto-Switch
Enabled feature in Guarded Access is set YES, the unit will automatically
switch to Electric Mode operation when standby power is connected and
available. The screens shown (
) (
) will
not appear.
If the unit is running in Diesel Mode and the Diesel to Electric Auto-Switch
Enabled feature in Guarded Access is set NO, the unit can be switched to
Electric Mode using the Electric Standby selection from the Main Menu.
From the Standard Display, press the MENU Key.
Figure 125.
Menu Key