TK 56171-2-OP-EN
105
From the Main Menu, choose Electric Standby and press the SELECT Soft
Key (
Figure 126.
Select Key
If the unit has standby power available and is turned on, the electric standby
run screen will appear. The new mode is confirmed for 10 seconds. The unit
will start and run in Electric Mode.
Any engine related Shutdown Alarms become Log Alarms when the unit is
switched to Electric Mode operation. If the unit is switched back to Diesel
Mode, these alarms again become Shutdown Alarms.
Electric Standby Power Fails or is Disconnected
If the electric standby power source fails or is disconnected and manual
switching to Diesel Mode is selected, the unit will prompt for a switch to
Diesel Mode (
Figure 127.
Diesel Mode Prompt
•
Pressing the YES Soft Key will switch unit operation back to Diesel
Mode.
•
Pressing the NO Soft Key will allow the unit to remain in Electric Mode
even though standby power is not available.
The unit will not run and Alarm Code 91 Check Electric Ready Input will be
set as a Prevent Alarm.