TK 56171-2-OP-EN
Hourmeter Name
Definition
Engine Reminder 2
User Programmable - The number of
hours before an Engine Run Time
Maintenance Reminder 2 occurs.
Electric Reminder 1
User Programmable - The number of
hours before an Electric Run Time
Maintenance Reminder 1 occurs.
Electric Reminder 2
User Programmable - The number of
hours before an Electric Run Time
Maintenance Reminder 2 occurs.
Engine Timing Belt
Accumulated Hours
Total number of hours the engine
timing belt has accrued in diesel mode.
IIm
mp
po
orrtta
an
ntt:: If a programmable hourmeter is not enabled or the view for that
hourmeter is not turned on it will not appear in the display
sequence.
Mode
The Mode Menu allows the operator to change the unit operating modes
that have been enabled in Guarded Access. Only Operating Modes that have
been enabled from the Guarded Access > Main Menu Configuration Menu
will be shown.
•
Turns Off Cycle Sentry Mode/Turns On Cycle Sentry Mode (If Cycle
Sentry is turned Off, unit runs in Continuous).
N
No
otte
e:: Selecting Cycle Sentry Mode or Continuous Mode can also be
accomplished using the Cycle Sentry Key to the right of the display.
•
Allows Single Zone Control to be selected (if enabled from the Guarded
Access > Main Menu Configuration Menu).
•
Allows temperatures to be displayed in either Fahrenheit or Celsius
degrees (if enabled from the Guarded Access > Main Menu Configuration
Menu).
•
Allows Keypad Lockout to be selected (if enabled from the Guarded
Access > Main Menu Configuration Menu).
•
Allows Sleep Mode to be set up and started (if enabled from the
Guarded Access > Main Menu Configuration Menu).
When shipped from the factory, only the Cycle Sentry/Continuous Mode is
enabled.
To return to the Main Menu, press the EXIT Key. To return to the Standard
Display, press the EXIT Key again.