1.4.5
Technical data sheet
MODEL
HC-14
HC-21
HC-30
HC-41
Flow (SCFM) @ 100 PSIG
100°F Drying Temperature
1204 1880 2708 3686
Vessel OD – Inches
24
30
36
42
Desiccant type
IR Activated Alumina
Lbs. Desiccant / Vessel
893
1395
2009
2735
Inlet connection
3 FLG
4 FLG
4 FLG
6 FLG
Outlet connection
3 FLG
4 FLG
4 FLG
6 FLG
FILTER
•
Afterfilter AF-1400
AF-2400
AF-3600
AF-7200
Voltage
115/1/60 Standard -
Consult Factory for other voltages
Cooling Water GPM
36
56
80
110
Stripping Flow SCFM
24
38
54
74
Cycle time
8 Hour NEMA Cycle –
4 Hours drying/ 4 Hours Regeneration
Outlet Dewpoint
Variable
DPDS Control
Adjustable
High Humidity Alarm
Adjustable
Pressure Switch Setpoint
10 PSI Fail to Shift 60 PSI Initiate Cooling
Cooler outlet high
temperature alarm
105
°
F
Low regeneration
temperature alarm
Adjustable
Process flow
Downward Regeneration / Upward Drying