USER MANUAL
Series HC
Reference No. 145 Final Rev 5
Page 16
September 2004
SECTION 1:
(Continued)
1.4.5
Technical data sheet
MODEL
HC-54
HC-69
HC-85
HC-103
Flow (SCFM) @ 100 PSIG
100°F Drying Temperature
4814 6093 7522 9101
Vessel OD – Inches
48
54
60
66
Desiccant type
IR Activated Alumina
Lbs. Desiccant / Vessel
3572
4521
5581
6753
Inlet connection
6 FLG
6 FLG
8 FLG
8 FLG
Outlet connection
6 FLG
6 FLG
8 FLG
8 FLG
FILTER
•
Afterfilter AF-7200
AF-7200
AF-7200
AF-10000
Voltage
115/1/60 Standard -
Consult Factory for other voltages
Cooling Water GPM
143
138
172
208
Stripping Flow SCFM
96
122
150
182
Cycle time
8 Hour NEMA Cycle –
4 Hours drying/ 4 Hours Regeneration
Outlet Dewpoint
Variable
DPDS Control
Adjustable
High Humidity Alarm
Adjustable
Pressure Switch Setpoint
10 PSI Fail to Shift 60 PSI Initiate Cooling
Cooler outlet high
temperature alarm
105
°
F
Low regeneration
temperature alarm
Adjustable
Process flow
Downward Regeneration / Upward Drying