USER MANUAL
Series HC
Reference No. 145 Final Rev 5
Page 36
September 2004
SECTION 4:
(Continued)
4.3
DEWPOINT METER MAINTENANCE (DPDS Option only)
NOTE: Refer to the Dewpoint Demand Installation & Operating Guide
included with this User Manual for information on dewpoint meter
maintenance and operation.
4.4
FILTERS
4.4.1
General comments and use
Filters of the series AF are suitable for filtering solids out of compressed air and
other neutral, compressed gases. This new filtration concept is characterized by
high flows at low differential pressure.
4.4.2
Function
The soiled medium flows through the filter element "Series AF" from the outside to
the inside. Solids are filtered out by impact or by the effect of inertia.
4.4.3
Assembly and installation
Advice
−
The piping system must be cleaned before assembling filter.
−
The filter must always be installed vertically.
4.4.4
Maintenance
Advice
−
The filter element should be replaced when a differential pressure of
> 10 PSID has been reached or, at latest, after 6 months of operation.