77700-084 

Rev. 

     07/02 

    Page 

9

 of 

13

 

75.0073 Nov 01 [Rev 8/8/2002]

 

PROGRAMMING - “CHEAT SHEET” 

 

Function Buttons 

Actions 

Factory Settings 

 
 

SENSITIVITY

 

Press this key followed by the number button  (0-9) of the 
sensitivity desired. 
0 - Minimum 
9 - Maximum

 

Door Closed = 8 

Door Open = 8 

 
 

RELAY HOLD TIME

 

Press this key followed by the number button (0-9) to enter 
the required hold time. 
0 = 1 second 

5 = 6 seconds 

1 = 2 seconds 

6 = 7 seconds 

2 = 3 seconds 

7 = 8 seconds 

3 = 4 seconds 

8 = 9 seconds 

4 = 5 seconds 

9 = 10 seconds 

1 Second 

 

PATTERN 

SELECTION

 

Press this key followed by a number button (1-9) to select the 
required pattern.  This setting can be selected for both states 
of the door, DOOR OPEN or DOOR CLOSED. 
1 = Wide pattern 

6 = Middle pattern  

2 = Middle pattern 

7 = Asymmetric left wide 

3 = Asymmetric left narrow 

8 = Asymmetric right wide 

4 = Asymmetric right narrow 

9 = Center narrow 

5 = Narrow left 

Door Closed = 1 

Door Open = 2 

 

RELAY MODE

 

Press this key followed by a number button (1-4) to select the 
required relay output desired. 
1- 

Passive output

, relay contact open during detection,  

closed during non-detection 

2- 

Active output

, relay contact closed during detection, 

open during non-detection 

3- 

Continuous detection

, relay contact always closed 

4- 

Continuous non-detection, 

relay contact always open 

Passive 

 

AUTO LEARN TIME

 

Press this key followed by a number button (1-9) to select the 
required auto learn time. 
0 = 30 seconds 

5 = 7 minutes 

1 = 1 minute 

6 = 10 minutes 

2 = 2 minutes 

7 = 15 minutes 

3 = 3 minutes 

8 = 20 minutes 

4 = 5 minutes 

9 = 25 minutes 

30 Seconds 

(0) 

 

FREQUENCY

 

Press this key followed by a number button (1-2) to select the 
required frequency. 
1 = normal frequency 
2 = random frequency 1 
3 = random frequency 2 

Random 

Frequency 1 

= 2 

 
 

INQUIRY

 

Press this button after pressing a function button.  Then count 
the number of times the LED flashes.  This corresponds to 
the status of the parameter in question. 

No Setting 

 
 

MAGIC  

WAND

 

Press this button followed by a number button to launch the 
desired set-up. 
1 = Launch closed door setup (door must be closed) 
2 = Launch open door setup (door must be open) 
3 = Automatic set-up 
4 = Reset to factory default settings 
 

No Setting 

 
 

PATTERN DEPTH

 

Press this button followed by a number button (1-3) to choose 
your desired pattern depth. 
1 = deep pattern 
2 = medium pattern 
3 = limited pattern 

Door Closed = 1 

Door Open = 1 

 

?

 

Summary of Contents for Dor-O-Matic 77700-900

Page 1: ...2002 77700 900 Presence Sensor Installation Instructions DOR DOR DOR DOR O O O O MATIC MATIC MATIC MATIC 7350 W Wilson Ave Harwood Heights IL 60706 Toll Free 1 800 543 4635 In Illinois 708 867 7400 S...

Page 2: ...ensor may also be tuned by means of two sensor mounted buttons contained on the PC Board within the unit With these two buttons the sensor s field of detection can be altered without the use of the ha...

Page 3: ...CB within the sensor housing is held in place by two white plastic support clips The clips are notched to allow the PCB to be set at 0 5 and 10 angles with the floor surface If a change in the angle o...

Page 4: ...nal block properly installed at the left side of the sensor terminal 1 will be farthest from the mounting surface and the screws for the terminals will be facing down The terminal block may be pulled...

Page 5: ...77700 084 Rev G 07 02 Page 5 of 13 75 0073 Nov 01 Rev 8 8 2002 WIRING DIAGRAM FOR SENIOR SWING MID SWING CONTROL...

Page 6: ...77700 084 Rev G 07 02 Page 6 of 13 WIRING DIAGRAM FOR ASCENT BENCHMARK PREMIUM CONTROL...

Page 7: ...assistance After the function button is pressed the red LED will flash rapidly 10Hz You will then have 30 seconds to make a numerical choice If a number is not entered within the 30 seconds the senso...

Page 8: ...nly change the parameters that are needed for your application INSTALLATION Position the sensor at the bottom of the header on swing side of the door Utilize the mounting block 87503 600 HMS Spacer wh...

Page 9: ...losed during non detection 2 Active output relay contact closed during detection open during non detection 3 Continuous detection relay contact always closed 4 Continuous non detection relay contact a...

Page 10: ...te the parameter and the green flashes indicate what that particular parameter is set to NOTE Pressing PB1 will toggle between the parameters and pressing PB2 will toggle between the range of adjustme...

Page 11: ...Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR 2 Middle Pattern Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8...

Page 12: ...e5 Zone6 Zone7 Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR Zone1 Zone2 Zone3 Zone4 Zone5 Zone6 Zone7 Zone8 Zone9 Zone...

Page 13: ...ctive Mode the relay contacts will be closed when the Red LED is on and open when the Red LED is off If the relay output when tested with an Ohm Meter is closed regardless of the Red Led and the Relay...