PRODUCT SPECIFICATION 

The 77700-900 Presence Sensor is an overhead-mounted diffused active infrared sensing device that provides 
detection for the triggering of automatic door safety functions. Applications include swinging, bi-folding and low-
energy door operation. 
 
The sensor is programmed to allow two different fields of detection - one for detection when the door is in the 
fully closed position and one for detection when the door is in the fully open position. While the door is in the fully 
open position, the sensor extends its coverage beyond the threshold area of the doorway, to allow coverage that 
will overlap that of the approach side motion sensor. 
 
As with all of Dor-O-Matic’s programmable sensing devices, full adjustability is achieved with the use of the 
74610-900 universal hand-held remote control unit. This allows alteration of all of the available functions as well 
as checking existing settings. Should the need arise, the sensor may also be tuned by means of two sensor-
mounted buttons contained on the PC Board within the unit. With these two buttons, the sensor’s field of 
detection can be altered without the use of the hand-held remote. 
 

TECHNICAL SPECIFICATIONS 

 

Installation Height - Variable 

9’-0” max. (recommended 6’-6” to 8’-0”) 

Mounting Angles 

0°, +5°, +10° (factory default setting: +5°) 

Power Supply 

24 V AC / DC +/- 10% 

Frequency 50-60 

Hz 

Output 

Max. voltage at contacts: 60V DC / 125V AC 
Max. current at contacts: 1 A (Resistor) 
Max. power supply:  30 W (DC), 120V (AC) 

Relay Hold Time 

1 to 10 seconds 

Operating Temperature 

-22°F to +140°F 

Immunity 

Immune to electrical and radio frequency interference 

Cable 6’-six 

conductor 

cable 

Weight 

1lb. 11 oz. (765g) 

Dimensions 

11.8”L (305 mm.) x 1.9”H (51 mm.) x 1.9”W (46 mm.) 

Material 

Aluminum & ABS plastic 

Housing Color 

Black anodized aluminum 

 
INSTALLATION PROCEDURE 

 
 
 
 
 
 
 
 
 
 
 

I. 

Disassembly of Sensor for installation 

Remove left & right end caps.  Slide the 2 lenses out.  Remove center eye-shield.  Remove PCB Board. 
 

II. Sensor 

Installation 

Install the sensor at the bottom of the header on the swing side of the door. 

Lens

Lens

Red / Green LED 

Aluminum Housing 

Center Eye Shield 

Lens Will Slide out when 
End Caps are removed 

Left End Cap 

Right End Cap 

Summary of Contents for Dor-O-Matic 77700-900

Page 1: ...2002 77700 900 Presence Sensor Installation Instructions DOR DOR DOR DOR O O O O MATIC MATIC MATIC MATIC 7350 W Wilson Ave Harwood Heights IL 60706 Toll Free 1 800 543 4635 In Illinois 708 867 7400 S...

Page 2: ...ensor may also be tuned by means of two sensor mounted buttons contained on the PC Board within the unit With these two buttons the sensor s field of detection can be altered without the use of the ha...

Page 3: ...CB within the sensor housing is held in place by two white plastic support clips The clips are notched to allow the PCB to be set at 0 5 and 10 angles with the floor surface If a change in the angle o...

Page 4: ...nal block properly installed at the left side of the sensor terminal 1 will be farthest from the mounting surface and the screws for the terminals will be facing down The terminal block may be pulled...

Page 5: ...77700 084 Rev G 07 02 Page 5 of 13 75 0073 Nov 01 Rev 8 8 2002 WIRING DIAGRAM FOR SENIOR SWING MID SWING CONTROL...

Page 6: ...77700 084 Rev G 07 02 Page 6 of 13 WIRING DIAGRAM FOR ASCENT BENCHMARK PREMIUM CONTROL...

Page 7: ...assistance After the function button is pressed the red LED will flash rapidly 10Hz You will then have 30 seconds to make a numerical choice If a number is not entered within the 30 seconds the senso...

Page 8: ...nly change the parameters that are needed for your application INSTALLATION Position the sensor at the bottom of the header on swing side of the door Utilize the mounting block 87503 600 HMS Spacer wh...

Page 9: ...losed during non detection 2 Active output relay contact closed during detection open during non detection 3 Continuous detection relay contact always closed 4 Continuous non detection relay contact a...

Page 10: ...te the parameter and the green flashes indicate what that particular parameter is set to NOTE Pressing PB1 will toggle between the parameters and pressing PB2 will toggle between the range of adjustme...

Page 11: ...Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR 2 Middle Pattern Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8...

Page 12: ...e5 Zone6 Zone7 Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR Zone1 Zone2 Zone3 Zone4 Zone5 Zone6 Zone7 Zone8 Zone9 Zone...

Page 13: ...ctive Mode the relay contacts will be closed when the Red LED is on and open when the Red LED is off If the relay output when tested with an Ohm Meter is closed regardless of the Red Led and the Relay...

Reviews: