Ingersol Rand Dor-O-Matic 77700-900 Installation Instructions Manual Download Page 7

 

77700-084 

Rev. 

     07/02 

    Page 

7

 of 

13

 

75.0073 Nov 01 [Rev 8/8/2002]

 

 

SETTING UP USING THE UNIVERSAL REMOTE 

 

The 77700-900 will automatically learn the door in the closed position after it is initially powered up – this is 
indicated by a flashing green LED. Then, the door must be activated so the sensor will learn the door in the open 
position. 

 

 

1. 

To Inquire about a Setting, complete the following:

 

 

• 

Unlock the sensor by pressing the Unlock key     . 

• 

Press the desired function button followed by the Inquiry 

?

 button.  The green LED on the sensor will flash a 

certain number of times to indicate the current setting.  For example, press the sensitivity button 

 followed 

by Inquiry 

?

 button.  The green LED will flash 8 times. 

 

2. 

To Change a Setting, complete the following: 

• 

Select the desired function button followed by a number.  Refer to the quick reference guide for assistance. 

• 

After the function button is pressed, the red LED will flash rapidly (+/- 10Hz).  You will then have 30 seconds 
to make a numerical choice.  If a number is not entered within the 30 seconds, the sensor will go back into 

Lock mode and keep the default setting.  For example, press the Auto Learn Time Button 

 followed by 

number 2.  The Learn Time will then be set for 2 minutes. 

• 

Once you are finished programming the sensor, you must then store the changes into permanent memory so 
they are retained if there is a power loss. Press the Lock key twice to retain all changes.  
 

3. 

To Save Changes, complete the following: 

• 

Press the lock button

   

twice.  The red LED will flash at a rate of +/-1Hz after pressing the lock button once.  

Then the red LED will turn off after pressing the lock button again. 

 

NOTE: The Bodyguard will Auto Learn (green LED flashing) if the sensitivity 

,

 pattern selection,            or pattern depth          

was changed during the set-up. 

Universal Remote Control 74610-900 

1

2

3

4

5

6

7

8

9

0

F1

F2

+

?

Function Buttons 

Number Buttons 

Unlock Button 

Lock Button 

Summary of Contents for Dor-O-Matic 77700-900

Page 1: ...2002 77700 900 Presence Sensor Installation Instructions DOR DOR DOR DOR O O O O MATIC MATIC MATIC MATIC 7350 W Wilson Ave Harwood Heights IL 60706 Toll Free 1 800 543 4635 In Illinois 708 867 7400 S...

Page 2: ...ensor may also be tuned by means of two sensor mounted buttons contained on the PC Board within the unit With these two buttons the sensor s field of detection can be altered without the use of the ha...

Page 3: ...CB within the sensor housing is held in place by two white plastic support clips The clips are notched to allow the PCB to be set at 0 5 and 10 angles with the floor surface If a change in the angle o...

Page 4: ...nal block properly installed at the left side of the sensor terminal 1 will be farthest from the mounting surface and the screws for the terminals will be facing down The terminal block may be pulled...

Page 5: ...77700 084 Rev G 07 02 Page 5 of 13 75 0073 Nov 01 Rev 8 8 2002 WIRING DIAGRAM FOR SENIOR SWING MID SWING CONTROL...

Page 6: ...77700 084 Rev G 07 02 Page 6 of 13 WIRING DIAGRAM FOR ASCENT BENCHMARK PREMIUM CONTROL...

Page 7: ...assistance After the function button is pressed the red LED will flash rapidly 10Hz You will then have 30 seconds to make a numerical choice If a number is not entered within the 30 seconds the senso...

Page 8: ...nly change the parameters that are needed for your application INSTALLATION Position the sensor at the bottom of the header on swing side of the door Utilize the mounting block 87503 600 HMS Spacer wh...

Page 9: ...losed during non detection 2 Active output relay contact closed during detection open during non detection 3 Continuous detection relay contact always closed 4 Continuous non detection relay contact a...

Page 10: ...te the parameter and the green flashes indicate what that particular parameter is set to NOTE Pressing PB1 will toggle between the parameters and pressing PB2 will toggle between the range of adjustme...

Page 11: ...Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR 2 Middle Pattern Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8...

Page 12: ...e5 Zone6 Zone7 Zone8 Zone9 Zone10 Zone11 Zone12 Zone13 Zone14 Zone15 Zone16 Zone17 Zone18 Zone19 Zone20 Zone21 Zone22 Zone23 Zone24 DOOR DOOR Zone1 Zone2 Zone3 Zone4 Zone5 Zone6 Zone7 Zone8 Zone9 Zone...

Page 13: ...ctive Mode the relay contacts will be closed when the Red LED is on and open when the Red LED is off If the relay output when tested with an Ohm Meter is closed regardless of the Red Led and the Relay...

Reviews: