ABB2000IKI01
65
Installation manual
Ingeteam
8. Display control
These inverters incorporate a display and keypad unit to interface with the
installer and the user.
This interface allows the display of the main internal parameters and the configu-
ration of the entire system during installation.
Parameters, variables and commands are organized as menus and submenus.
8.1. Keypad and LEDs
The keypad has four keys:
Esc.
To exit a parameter, leave a menu and returning to the next level up in the structure, to not
confirm a change or not accept a suggestion.
Up.
With this key you can scroll up the list of parameters or folders within the same level or
increase the value of an editable parameter by one base unit.
Down.
With this key you can scroll down the list of parameters or folders within the same level or
decrease the value of an editable parameter by one base unit.
OK.
Serves to accept a parameter as valid, to enter a lower level menu in the structure, to confirm
a change or accept a suggestion.
The front panel has three LEDs:
Green LED
•
Slow flashing: Standby due to low irradiance.
•
Fast flashing: Start-up process.
•
On: Inverter connected to the grid.
Orange LED
Fast flashing: Alarm set off which does not shut down the inverter.
Red LED
On: Alarm set off which shuts down the inverter.
Special combinations
Rapid flashing of all three LEDs: Fatal error status.