88
Chapter 3 - Device Profile
CD1-k – CANopen Communication Profile
3.13.9.2 - Object 3414h: Motor phasing procedure
Writing to this object will execute the motor phasing procedure. This command starts the motor phasing procedure
after the amplifier power up when incremental encoder types without Hall Effect Sensors are used (see
CD1-k
manual
). INHIBIT input must be desactived.
Index 3414h
Name
Motor phasing procedure
Object Code
VAR
Data Type
Unsigned32
Object Class
-
Access wo
PDO Mapping
No
In order to avoid running the motor phasing procedure by mistake, the motor phasing is only executed when a
specific signature is written to the this object. This signature is 'mcal'.
Signature MSB
LSB
ASCII l
a c m
hex 6Ch 61h 63h 6Dh
3.13.10 - AUTO-TUNING FUNCTION
3.13.10.1 - Object 3421h: Auto-tuning Time Interval Selection Mode
Index 3421h
Name
Auto-tuning Time Interval Selection Mode
Object Code
VAR
Data Type
Unsigned16
Object Class
ip pp hm pv
Access rw
PDO Mapping
No
Value Range
0..1
0 -> manual setting of "Time Interval Speed Measurement " parameter
1 -> automatic setting of "Time Interval Speed Measurement " parameter by auto-
tuning.
This parameter must be set before starting the auto-tuning.
Default Value
eeprom
3.13.10.2 - Object 3430h: Auto-tuning Application Requirements
Index 3430h
Name
Auto-tuning Application Requirements
Object Code
VAR
Data Type
Unsigned16
Object Class
ip pp hm
Access rw
PDO Mapping
No
Value Range
0..1
0 -> Minimum tracking error
1 -> Minimum overshoot
This parameter must be set before starting the auto-tuning.
Default Value
eeprom