background image

Thermal imager (including the connecting socket, lens hood, and eye cup): 1SET
Operation and Maintenance Manual: 1PCS

1.Lower box cover;  2.Foam;  3.Lower blister cover; 4.Upper blister cover;  5 Upper 
box cover; 6.Manual; 7.Thermal imager;

9   Package List

1

2

6

4

3 7

5

Take necessary anti-static and anti-shock 
measures for the product during storage. 
Control such activities as storage, packaging, 

All facilities and stored items should be 
kept clean and tidy.
Storage places should have good lighting 
facilities.
The  storage  environment  should  be  far 
from strong magnetic field.
Places  with  adequate  facilities  for 
earthquake  prevention,  fire  prevention, 
ventilation, heat insulation, heat preservation, 
drainage, etc.
Do not place the imager near the source 
of  heat  radiation.  Keep  it  at  least  1.5  m 
away from the heat source. Do not place 

8.2.2Inspection during Storage

it in a place directly exposed to sunlight 
for a long time.
Prohibit  storing  items  that  have  a 
corrosive effect on the imager.

and  protection  in  accordance  with  the 
requirements to ensure that the product 
features will not be impaired.
a) Before storage, check the completeness 
of  the  product.  Ensure  that  the  module 
component, packaging, and accessories 
are clean and dry;
b)  Periodically  inspect  products  during 
storage.  In  case  of  any  problem,  timely 
solve it.

13

Tyke-L3 

Operation and Maintenance Manual 

Summary of Contents for Tyke-L3

Page 1: ...Tyke L3 Thermal Imager IRay Technology Co Ltd OperationandMaintenanceManual V1 0 2...

Page 2: ...d brush Do not wipe it with ngers or dirty cloth Protect the thermal imager from falling or severe impact Cautions Please do not power the thermal imager to reduce battery energy consumption when it i...

Page 3: ...peci cations 3 Package and Label 3 3 3 4 4 1 Focus Knob 4 2 Power Button 4 3 Encoder Aviation Connector Interface 4 4 4 Encoder 4 4 5 Diopter Regulation Knob 4 Functional Components and Interface 4 5...

Page 4: ...tion and Storage 9 Package List 13 12 12 8 1 Transportation 8 2 Storage 6 3 4 Image Transmission 6 3 5 Infrared Image 6 3 6 Zero Calibration 6 3 7 Reset Preset Menu 6 3 8 Reticle Setup 6 3 9 Other Set...

Page 5: ...tion adjustment g Reticle selection and adjustment h Auto detection of faults i Reverse polarity protection and over discharge protection for battery j Light leaking prevention The technical speci cat...

Page 6: ...ture StorageTemperature Humidity Altitude Encapsulation ReticleAdjustmentRange L325 L335 18650 Lithium battery 8h 190 76 82mm 450g 193 76 82mm 485g 10s IP67 400m 600m 600m 850m 15mil 40 55 50 70 95 3...

Page 7: ...a special white packaging box with black matte blister box as inner lining and foam at bottom which is not easy to be damaged during transportation For details please take package list for reference...

Page 8: ...to adjust the clarity of the display screen which can be adapted to the observation of myopia and hyperopia glasses 4 5 Diopter Regulation Knob The thermal imager is directly connected to the Picatin...

Page 9: ...Picture Caution it is not allowed to press the encoder during rotating After the battery is installed and can supply power normally long press the power button for 5 seconds to get the thermal imager...

Page 10: ...the Screen brightness menu turn the encoder roller to adjust the brightness After getting the right brightness short press the encoder to x the device at the current brightness as shown in Figure 7 o...

Page 11: ...ss approach for simultaneous observation coordinatedcommand andquickdirections Itcanbeperformedthrough head mounted transmission wireless transmission or analog videos disabled by default must be enab...

Page 12: ...e surrounding environment brightness Contrast adjustable between 0 100 0 by default Brightness and contrast ranges between 0 100 Turn the encoder clockwise to increase the value or anticlockwise to de...

Page 13: ...ou can move the reticle leftward or rightward on the screen by adjusting the position correction parameters Turn the encoder clockwise to increase the values and move the reticle rightward or anticloc...

Page 14: ...rse mode the reticle color is adjusted according to the background color The reticle is black against bright background and is white against dim background Save and exit Press OK to exit to the rst le...

Page 15: ...nt cannot be enabled or disabled normally 1 3 4 5 No Fault Cause Troubleshooting Method 2 English options You can select based on your language preference There will be cues for the separate language...

Page 16: ...lighting facilities The storage environment should be far from strong magnetic eld Places with adequate facilities for earthquake prevention re prevention ventilation heatinsulation heat preservation...

Page 17: ...vitiesasstorage packaging 8 2 2Inspection during Storage it in a place directly exposed to sunlight for a long time Prohibit storing items that have a corrosive e ect on the imager and protection in a...

Page 18: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whic...