47
shelter alarm, SD card out, network link down or IP address conflict. Default:
Local Contact.
Net Contact: I/O out is controlled by the surveillance management software.
Note:
This function needs to be supported by digital video surveillance
management software like V2216. If Net Contact is selected, users have to set
Alarm Server IP the same as the IP address of V2216-CMS server. After
related setting to V2216 finished, users can remotely control the relay via
V2216 software. For detailed information, please refer to V2216 manual.
Alarm Server IP: used to set the IP address of alarm server. If alarm occurs, it
will inform the alarm server.
Alarmout Contact
Users can set the relevant alarm response ways for I/O alarm in, motion
detection alarm, shelter alarm, SD card out, network link down or IP address
conflict: Alarm out 1 (if Net Contact is selected, Alarm output 1 on the web
page is unavailable), SD card, Mail, FTP or Audio. After setting completed,
click “Save” button to take effect.
Note: when “FTP” or “Mail” is selected, you need to set FTP or SMTP
parameters in Network Settings, refer to Section 4.3.2 or Section 4.3.3 for
details.
Alarm Schedule
V6202-T00&V6202-T02 series camera can set the effective alarm schedule.
Select the alarm period (if Sunday is selected, alarm will be enabled during the
set period of each Sunday; if everyday is selected, alarm will be enabled during
the set period of everyday), and then, set the time period. Enter the start time
and end time in the 24-hour format. The end time must be larger than the start
time.