7
and enable FTP alarm in alarm settings, then alarm associate with
FTP upload can be achieved.
3.4.4 SMTP Settings
z
Server IP: Set mail server address.
z
From: Set sender’s mail address.
z
To: Mail address of recipient.
z
CC: Mail address of the person copy to.
z
Authentication: Enable or disable authentication function. This
function should be set according to authentication requirements
of mail server.
z
User name: Sender’s name, it can be set according user’s needs.
z
Password: Set sender’s password.
z
Note: there is no limit for Sender’s name and password settings.
After setting completes, click “Set” button to take effect.
If user selects “mail” in “Alarm Settings” interface, system will
send mail according to SMTP settings.
3.5 Time Settings
Click
button in the navigation bar to display the
following Time Zone Settings interface:
Figure 3-17
Time zone:
Select the desired time zone in the scroll box, and then
click “Set” to save it.
There are 26 time zones for selection:
GMT-12:00~GMT~GMT+13:00, and the default setting is GMT
Greenwich Mean Time.
For Daylight Saving Time enable region, please tick “Automatically
adjust clock for daylight saving changes”.
Synchronize with computer time:
used to check whether the time
of system is the same as that of local PC. Click “Set” to adjust.
Synchronize with NTP server:
whether to select NTP server or not.
Select “NTP” to enable NTP server, or otherwise disable NTP
server.
If NTP server is selected, you can input NTP server address into IP
bar. Click “Set” to finish. If so, the system will adjust time with
NTP server automatically.
3.6 Alarm settings
Click
button in the navigation bar to display the
following Alarm Settings interface:
Figure 3-18
I /O In
: Settable 2-channel alarm input In1/In2.
Each alarm input has 2 modes
(1)
Grounded Circuit
(2)
Open Circuit
Recommended:
Grounded Circuit
Alarm out Contact: used to set sending way of alarm.
Local Contact:
unable to send alarm through net, only local
alarm output. Default: Local Contact.
Net Contact:
send alarm via net.
Note:
This function needs to be supported by digital video
surveillance management software like V2216. If Net Contact is
selected, user has to set Alarm Server IP the same as the IP address
of V2216-CMS server. After setting finished, user can remotely
control the relay via V2216 software. For detailed information,
please refer to V2216 manual.
Alarm Server IP:
used to set the IP address of alarm server when
NET contact is selected. If alarm occurs, it will inform the alarm
server.
Users can set alarm handling ways for alarm input or motion
detection alarm, like sending Mail, FTP upload, audible alarm, SD
storage (trigger recording), Relay output (1 channel). After setting
completes, click “Set” button to take effect.
3.7 PTZ Settings
Click
button in the navigation bar to display the
PTZ Setting box:
Figure 3-19 PTZ Interface