18
prompts to confirm the center of privacy area.
Notice: the vertical angle shall be less than 70°.
Step 4: get the PTZ camera to pan and tilt to set the area size. After
settings, click the button “Apply”.
Then, the privacy mask is properly set.
Note:
the number of privacy areas is subject to the built-in HD
camera module. Hitachi’s camera module supports up to 4 areas;
Sony’s supports up to 24 areas; Panasonic’s supports up to 15 areas.
4.6.7 IR Lamp
Fig. 4-40 IR Lamp
On the interface, users can set the “Open mode” of the IR lamp,
with On, Off, Auto optional. In “Auto” mode, the “Open mode” of
the IR lamp is controlled by the ambient light, when the light level
is lower than the Threshold level, the IR lamp will be turned on,
and when the light level is higher than the Threshold level, the IR
lamp will be turned off. Adjust the “Open Sensitivity” to set the
Threshold level.
Fig. 4-41 Sensitivity Settings
The Threshold level of sensitivity can set to 0~10, which could be
adjusted according to light conditions.
Fig. 4-42 Power Settings
Power Set
: Adjusting the power can change the IR lamp brightness
for different digital zoom level. When the ambient light is proper,
and with small digital zoom level, the power can be set at a low
level; but if the ambient light is not good enough and the digital
zoom level is big, the power shall be set to a higher level.
4.6.8 Special Functions
Fig. 4-43 PTZ Special Settings
V1492MR-T series supports analog video output and RS-485
control. In the special function settings interface, you can set the
camera ID and baud rate. (Notes: camera ID and baud rate DIP
must be set to ON. For DIP settings, please refer to Appendix I.)
Work Mode: normal, energy-efficient or anti-gale.
Vertical Work Mode: normal or energy- efficient.
4.7 Time Function
Fig. 4-44 Time Function
Under mode calling, you can set the Act Mode and Act Time.
Timed tour is more flexible than the normal tour.
Summary of Contents for V1492MR-18TH