FY operation manual
- 37 -
Figure10-2-11 Bidirection compensate image
4) Press
“
”
button, print the bidirection compensate image.
5) Check the image to find a straight line. Reset the values on Adjustment \ Bid adjust according to
the data above the line.
6) Follow the same steps above, get Bidirection compensate results at different speed setting.
3
、
Feed compensate
There are different feed compensate results for different pass number you selected.
To compensate feeding on Y direction, following by:
1) Select 360x180 1Pass
,
Adjustment\Rectangle on operation control board is not available for
6250LQ. Press ONLINE make printer Online Mode.
2)
In 6320LQ Try
,
open testing file named 180.group
Figure 10-2-12 Feeding compensation image (180.group)
3) Press
“
”
button
,
start to print
4) Check the swatch, see if the lines are even (better check by microscope); if not, back to Figure
10-2-7 to adjust parameters until all lines are even, then click on “OK”.
5) When select 360x270 1Pass
,
open 270.group, following the rules above to reset the parameters,
and then click on “OK”.
6) Step1 to 4 can be applied for different pass settings.
4
、
Print head voltage curve
Press
“
Voltage Curve
”
button, pop up a dialog box as below: