Siting the Appliance

 

 
 

PREPARING THE OPENING FOR INSTALLATION WITH MARBLE SLIPS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The front face and the base of the fire opening must be flat to ensure that a good seal is formed between the 
rear and base of the appliance and the chimney to avoid any reduction of natural draught.

 * Please note: It is 

important to ensure the bottom of the firebox is completely sealed to reduce the risk of excess sooting 
resulting from incomplete combustion. 

 
 
Locate  the  slip  mounting  frame  (supplied  as  an  optional  extra)  by  hooking  onto  the  existing  studs  on  the 
firebox with the fireplace frame already located. 
 

Class one Installation with a flexible liner using optional gather hood (Part No A-0293) 

 

Route the flexible liner within the brick built flue as of the requirements stipulated by the 

liner manufacture. 

 

Attach the gather hood to the liner using a suitable fixing at a height that clears the out 

fire box assembly. 

 

Remove  the  inner  box  and  top  inspection  cover  as  described  in  section  five  general 

points. 

 

With the out fire box in place, attach the gather hood to the fire box using the four fixing 

screws provided within the kit. 

 

Re- assemble in reverse order. 

Clearance to Shelf 

 

Minimum  clearance  from  hearth  or  base  of  opening  to  underside  of  combustible  shelf  should  be  800mm 
provided the shelf depth is 75mm (3”). This gives a minimum clearance above the appliance of 140mm. For a 
shelf of 150mm (6”) the minimum height above the hearth or base of opening must be 880mm. This will give a 
minimum clearance above the appliance of 220mm. 

 

Clearance to Sides of Fire 

Minimum width between vertical sides of combustible surround should not be less than 875 mm provided fire 
is central to the surround and sides do not project more than 150 mm. When vertical side forward projection is 
increased by 12.5 mm add 50 mm to inside width of surround.

  

 
 
 
 

 

625 - 665mm 

635- 640mm 

350mm  
Min Min  

 

Floor 

 

This area behind the trim/fascia 
must be clear of combustible 
material and be flat for the seal. 

 

 

Summary of Contents for 480 FL

Page 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IREL...

Page 2: ...l Bed Layout 10 SECTION FIVE General Points 12 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 13 SECTION SEVEN Regulations and Warnings 14 SECTION EIGHT Siting the Appliance Flue Class1 15 SECTI...

Page 3: ...cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these...

Page 4: ...otland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accorda...

Page 5: ...from manual to Room Thermostat setting and vice versa When Room Thermostat mode is active the display shows the set temperature value and the AUTO icon will appear on the LCD display By using the arr...

Page 6: ...y for three seconds the written clock will appear To change the clock settings repeat the above described operation Change From Celsius to Fahrenheit With remote OFF keeping pressed key at least for 5...

Page 7: ...REPLACE APPLIANCE BATTERIES 6 High Power Alkaline C 1 5V a Remove the fireplace frame covers which are held in place with magnets b Lift out the air grill cover from the bottom of the frame assembly c...

Page 8: ...blow the debris into the hole as this may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From...

Page 9: ...th great care The moulded shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose componen...

Page 10: ...yout Please make sure no loose shapes are placed directly on top of the pilot shield Place the 2 log shapes along the front edge of the burner top plate Place a single layer of small bark chippings al...

Page 11: ...ers Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place the 2 log shapes along the rear of the air tray assembly Position a single layer of bark chippings along the front edge of the air tray...

Page 12: ...12 LT 6117 12 13 Iss 11 480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the two log shapes as shown Place the two log shapes as shown...

Page 13: ...then pull clear and remove from location studs Carefully lift the glass panel from within the bottom retaining slot Remove the log fuel bed shapes Lift out the air tray assembly from the location poi...

Page 14: ...iance 6 x 1 5V C high power alkaline Appliance Dimension NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 73 67 The gross calorific value...

Page 15: ...he appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rul...

Page 16: ...5 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the opening into the li...

Page 17: ...le fixing at a height that clears the out fire box assembly Remove the inner box and top inspection cover as described in section five general points With the out fire box in place attach the gather h...

Page 18: ...liance GAS SUPPLY ROUTING Use rigid or semi rigid tube to connect the supply Determine the gas supply pipe route to the appliance before installing the fire Fixing Firebox Assembly Slide the firebox i...

Page 19: ...n 502mm from the centre of the firebox The horizontal stud work should not be less than 764mm from the base of the firebox This will ensure 50mm minimum clearance from the sides and 110mm clearance fr...

Page 20: ...the fault corrected if the fault cannot be corrected disconnect the fire from the gas supply and seek expert advice Spillage can be caused by a restriction in the flue system down draught or insuffici...

Page 21: ...R TRAY Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Remove gas supply cover Disconn...

Page 22: ...n the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefu...

Page 23: ...23 LT 6117 12 13 Iss 11...

Page 24: ...date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registration Form must be correctly filled out and returned 7 The a...

Page 25: ...25 LT 6117 12 13 Iss 11...

Page 26: ...Date of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registratio...

Page 27: ...27 LT 6117 12 13 Iss 11...

Page 28: ...YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model 480 FL Serial No Date of Purchase This information can be found...

Page 29: ...29 LT 6117 12 13 Iss 11...

Page 30: ...30 LT 6117 12 13 Iss 11...

Page 31: ...31 LT 6117 12 13 Iss 11...

Page 32: ...ing Label 1409 ID Label Packing Labels Side Covers 6016 Restrictor Plate Inlet Cover 6006 Serial Number Inspector Infinity 480 FL Product ID Label A 0342 Serial No Prefix MY Lpg Burner Tray Box Assemb...

Reviews: