Appliance Data
NATURAL GAS
PROPANE GAS
Gas Type:
CATEGORY I 2 H
CATERGORY 1 3 P
Gas Pressure:
20 mbar +/- 1.0mbar 37 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
5.5 kW Gross (Max.)
5.0kW Gross (Max.)
2.4 kW Gross (Min.)
2.4kW Gross (Max.)
Injectors:
Mk 360
Mk 116
Oxy pilot:
9102 N.G.
9264 L.P.G.
NOx Classification ……………….. 5
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location:
Located on the base of the appliance on the R/H side beneath the
grill.
Battery
Remote handset size 3 x 1.5v AAA,
Appliance 6 x 1.5V C high power alkaline.
Appliance Dimension
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 +A1:2013
and the result is 73.67 %. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating
of dwellings.
Please note:
Within the appliance packaging will be a outlet restrictor, this is there to
achieve the maximum efficiency. This, however, may not be fitted due to the flue underperforming.
When unpacking the appliance please check the following items are included:
Fuel Bed:
Air Tray
Fireplace Frame Assembly.
Owners Manual
Vermiculite
Summary of Contents for 480 FL
Page 23: ...23 LT 6117 12 13 Iss 11...
Page 25: ...25 LT 6117 12 13 Iss 11...
Page 27: ...27 LT 6117 12 13 Iss 11...
Page 29: ...29 LT 6117 12 13 Iss 11...
Page 30: ...30 LT 6117 12 13 Iss 11...
Page 31: ...31 LT 6117 12 13 Iss 11...