Other reasons for air leakage
1. The SPA was not inflated in the place of use. After inflation, the SPA was moved to the place of use, thereby damaged the UPVC body.
2. Surface not even and stable.
3. The SPA has been overinflated.
Only inflate the SPA to the point where the upper edge can still be pressed in approx. 1 - 1.5 cm with the palm of your hand.
The air inside expands further in the sun, which can lead to damage to the UPVC shall if the SPA is inflated too much.
If the spa is filled with too much air, this can cause both deformation and over-stretching of the UPVC cover. Over-stretching of the UPVC
shell is the main cause of irreparable tearing of the welding seams.
In these three cases, Ubbink Garden BV reserves the right to reject guarantee claims.
B. Loss of water
Before filling the SPA with water, the water outlets inside / outside the SPA should be checked again for their watertight seal.
1. In the SPA
• Check if the rubber plug is inserted correctly and waterproof
2. Outside the SPA
• Check the screw cap to make sure the sealing ring is inserted properly
and that it is tightened hand-tight.
C. FILTER SYTEM
Pumping noise
An increasing noise level of the pump is usually caused by an insufficient water flow or a
pump problem itself. The following procedure should be followed to identify and solve the noise problem
- Check the water level and top up the water if necessary (check the min./max. level)
- Unscrew the filter cartridge and check the pump noise (without filter cartridge)
- After 15-20 minutes, screw on a new or cleaned filter cartridge
No filtering
If there is the impression that the filtering does not work properly or at all, the following procedure should be followed:
- check on the display that the filtering is switched on
- check the filter cartridge for contamination. If dirty, clean or replace the filter cartridge
- Check the water flow. For this, unscrew the filter cartridge and use your hand to
• feel whether the filter pump is drawing water at the water inlet.
• feel whether water is coming out of the water outlet
D. HEATING SYSTEM
Problems with the heating are generally
1. Insufficient water flow due to a low water level or a dirty filter cartridge.
If not enough water flows through the heater, the temperature sensor cannot determine the current water temperature and the water cannot
be heated properly.
Measures:
- Check the water level and top up the water if necessary (observe the min./max.)
- Unscrew the filter cartridge and replace it with a new or cleaned one
2. Wrong or incomplete programming of the desired water temperature
Programming of required temperature:
1. Ensure that the heating system (HEATER) is switched on.
2. Press the TEMPERATURE button (the numbers on the control panel now flash continuously)
3. Use the arrow buttons TEMP UP / TEMP DOWN to select the required water temperature.
4. When the desired temperature is displayed on the control panel, press the TEMPERATURE button again. The temperature is now set and
programmed.
5. Press the HEATER button to start the heating system. On the display, a red LED now lights up next to HEATER and FILTER: The system
now starts automatically with water circulation.