SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
88
Revision 1.0, 2011-12-15
2.21.7
Execution Information
Table 96
SMulIntInt: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
–
75
81
µs
DIVIC = 00
H
Charge Consumption
Q
–
0,112
0,194
µC
DIVIC = 00
H