SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
40
Revision 1.0, 2011-12-15
Charge consumption in
automatic range selection
Compensated Pressure result
with new raw temperature
measurement, 2 samples
Q
autocomp,
new
–
1,644
2,519
µC
DIVIC = 00
H
,
SensorConfig = 0481
H
,
SampleRate = 00
H
Charge Consumption in
automatic range selection
compensated when supplied
with previously obtained raw
temperature value, 2 samples
Q
autocomp,
prev
–
1,196
1,873
µC
DIVIC = 00
H
,
SensorConfig = 0581
H
,
SampleRate = 00
H
Charge Consumption in
automatic pressure range for
each additional sample for
averaging
Q
autosampl
e
–
0,118
0,148
µC
SampleRate = 00
H
Only 1, 2, 4, 8, 16, 32, 64 samples
possible
1) The execution time and charge consumption for automatic range selection have been verified when the proper pressure
range is selected.
Table 18
Meas_Pressure: Execution Time and Charge Consumption
(cont’d)
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.