SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
120
Revision 1.0, 2011-12-15
2.36.5
Outputs
2.36.6
Resource Usage
2.36.7
Execution Information
Table 154
GetCompValue: Output values
Register/ Address
Type
Name
Description
R7
unsigned char Compensated Value Returns the compensated value from the lookup
table defined by selected column and row
Table 155
GetCompValue: Resources
Type
Used or Modified
Registers
R0, R1, R3, R5, R6, R7
SFR
ACC, DPH, DPL, PSW, SP
Stack
2 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 156
GetCompValue: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
–
619
669
µs
DIVIC = 00
H
Charge Consumption
Q
–
0,929
1,606
µC
DIVIC = 00
H