SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
119
Revision 1.0, 2011-12-15
Figure 15
Lookup table organization
NV2
NV1
Number ([M -1] = 1=one , 2=two,…, 14=fourteen ) of threshold
points for Value2 (e.g. voltage)
Number ([N -1] = 1=one, 2=two,…, 14=fourteen ) of threshold
points for Value1 (e.g. temperature )
V1.1
V1.2
First threshold for Value1
Second threshold for Value1
V1.N
Final threshold for Value1 (N -1 = 1...14)
V2.1
First threshold for Value2
V2.M
Final threshold for Value2 (M - 1 = 1...14)
Compensated values 1, 2, …, M
for
measured Value1
(e.g. temperature ) < V1
sorted in increasing order of Value2 (e.g. voltage) threshold .
Compensated values M + (1, 2, …, M)
for V1.1 <
measured Value1
< V1.2,
sorted in increasing order of Value2 threshold .
Compensated values (N-2) * M + (1, 2,…, M)
for V1.N-1 <
measured Value1
< V1.N,
sorted in increasing order of Value2 threshold.
Compensated values (N-1) * M + (1, 2,…, M)
for V1.N <
measured Value 1
sorted in increasing order of Value2 threshold.
upper
half-byte
lower
half-byte
TableP 0
TableP 1
TableP+
TableP 2
<V1.1
<V2.1
<V1.1
<V2.2
<V1.1
<V2.M
CompValue 1
CompValue 2
CompValue 14
<V1.1
>V2.M
CompValue M
<V1.2
<V2.1
<V1.N
<V2.1
>V1.N
<V2.1
TableP+