SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
116
Revision 1.0, 2011-12-15
2.35.6
Resource Usage
2.35.7
Execution Information
Table 151
HIRC_Clock_Check: Resources
Type
Used or Modified
Registers
R0, R1, R2, R3, R4, R5, R6, R7
SFR
ACC, B, CFG0, DIVIC, DPH, DPL, PSW, TCON, TH0, TH1, TL0, TL1, TMOD
Stack
5 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 152
HIRC_Clock_Check: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
OFF
–
3430
5210
µs
DIVIC = 00H, XtalOSC is OFF at the start
of the function
Execution Time
t
ON
–
820
891
µs
DIVIC = 00H, XtalOSC is ON at the start
of the function
Charge Consumption
Q
OFF
–
3,81
8,69
µC
DIVIC = 00H, XtalOSC is OFF at the start
of the function
Charge Consumption
Q
ON
–
1,48
2,35
µC
DIVIC = 00H, XtalOSC is ON at the start
of the function