SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
106
Revision 1.0, 2011-12-15
2.30.5
Outputs
2.30.6
Resource Usage
2.30.7
Execution Information
Table 130
WriteFlashUserConfigurationSectorLine: Output values
Register/ Address
Type
Name
Description
R7
signed char
Statusbyte
0: success
-1: failed
Table 131
WriteFlashUserConfigurationSectorLine: Resources
Type
Used or Modified
Registers
R0, R1, R2, R3, R4, R5, R6, R7
SFR
ACC, CFG1, CRC0, CRC1, CRCC, CRCD, DIVIC, DPH, DPL, PSW, TCON, TH0,
TH1, TL0, TL1, TMOD
Stack
5 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 132
WriteFlashUserConfigurationSectorLine: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
1)
1) Values are obtained by extrapolation, not by characterization
t
–
3917
4260
µs
DIVIC = 00
H
, FLASH written with all bit 1
Charge
Consumption
Q
–
8,97
12
µC
DIVIC = 00
H
, FLASH written with all bit 1