Application Note
10 of 63
V 1.2
2018-12-12
5 Output PMIC Controller/ IRPS5401
User guide with DB295 and DB296 demo boards
Figure 11
Tracking mode
3.3
Fault settings
All PMBus OV and UV CMD’s are READ ONLY for the LDO. A read command will report back the percentage of
VOUT shown in the table below. POWER_GOOD_ON and OFF is a read only command in tracking mode.
Table 2
Address offset table
MODE
Source Only
Tracking
Parameter
% of ldo_target_vout
% of ½*VIN_LDO
UV_FAULT
75
75
UV_WARN
87.5
87.5
OV_WARN
112.5
112.5
OV_FAULT
125
125
PG_ON
POWER_GOOD_ON
87.5
PG_OFF
POWER_GOOD_OFF
81.25