5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not e
x
tinguished.
Be careful of the spark plug wires and the
thermocouple tubes.
The oven burner does not require primary air
adjustment.
After adjusting the appliance so it may be used
with a different type of gas, replace the old rating
label with a new one which corresponds to the new
type of gas (these labels are available from
Authorised Technical Assistance Centres).
Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating
to regulators for channelled gas.
TECHNICAL DATA
Oven dimensions
(HxWxD)
31x43.5x43.5 cm
Volume
58 l
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with
any type of gas shown on
the data plate
EC
Directives:
2006/95/EEC
dated 12.12.06 (Low
Voltage) and subsequent
amendments - 89/336/EEC
dated 03/05/89
(Electromagnetic
Compatibility) and
subsequent amendments -
90/369/EEC dated 29/06/90
(Gas) and subsequent
amendments - 93/68/EEC
dated 22/07/93 and
subsequent amendments -
2002/96/EC.