PAGE 4
9
ø 6
mm
f
e
PN80499
Remove the tie bar assembly from the panel.
a:
Unscrew the wall bracket from the end of the tie bar bracket.
b:
Place the wall bracket in the marked position and mark the fixing hole onto the wall.
c:
Drill the position marked using a 6mm drill bit, 30mm deep.
d:
Insert the wall plug and fix the wall bracket to the wall using a 32mm screw and washer.
Note:
The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e. stud
partitions, plasterboard etc, use the correct type of fixings.
e:
Screw the tie bar bracket back onto the wall bracket.
f:
Reposition the tie bar into the tie bar bracket and the other end (with top panel bracket fitted) onto the
panel (with grub screw on the inside). Tighten the tie bar bracket grub screw onto the tie bar.
g:
From inside, tighten the grub screw (
1
) onto the panel.
Ensure the panel is vertical and tighten the grub
screw in the top of the bracket onto the tie bar (
2
). Push fit the screw cover cap.
10
Push fit the top cap onto the top of the wall channel.
32
mm
a
1
2
c
d
g
Inside
b
3mm
2mm
11
Without threshold strip
- from outside only, seal along the bottom of the panel and wall channel, 50mm up the wall channel and the joint between the wall channel and panel.
Aluminium threshold strip
- from inside and outside, seal along the bottom and top of the threshold strip.
From outside only, seal along the bottom of the wall channel, 50mm up the wall channel and up the joint between the wall channel and threshold strip.
Plastic threshold strip
- from outside only, seal along the bottom of the wall channel, 50mm up the wall channel and the joint between the wall channel and threshold strip.
Outside -
Aluminium threshold strip
Outside -
Plastic threshold strip
Outside -
Without threshold strip