IP Engine Install
From DOS prompt navigate to the folder where the IGV file is located then run the installer
using the IGV file then a space and use parameter –n followed by the serial number of the
camera xxxxxx.
Make sure you have the correct IP Engine for the camera model IGV xxxx.exe application.
Use the file name IGVxxxx.exe –n123456 (need a space between the .exe and
the -n)
This loads the serial number back into the camera.
Select the IP engine file and click OK.
After successful completion of the update close the window and power cycle the camera.
CAUTION NOTE
It is strongly recommended that you DO NOT USE any other communication software to
upgrade the camera FW, RGS, DPC, HPC, FFC and LUT files.
If the user selects to upgrade camera firmware and camera factory register space, the camera
firmware must be upgraded first.
During camera RGS or FW upgrade the camera power must be on all the time, and the process
must not be interrupted. If the camera is disconnected or the process canceled, this will result
in a user application firmware corruption. If such event occurs start the upload process again
until completion. If the upgrade process cannot be completed, the camera will power with the