CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
251 of 329
Data (11:0)
: 0x001 – min travel distance (GUI slider, Wide)
: 0xFFF – max travel distance (GUI slider, Narrow)
Data (23:16)
: 0x1 – Zoom Wide (slider/window #), (GUI, <)
: 0x2 – Zoom Narrow (slider/window #), (GUI, >)
: 0x4 – Zoom Wide (full, 0xFFF pulses), (GUI, <<)
: 0x8 – Zoom Narrow (full, 0xFFF pulses), (GUI, >>)
: 0x10 – Zoom Stop
Data (15:12)
: N/A
Data (31:24)
: N/A
4.5.1.4
Zoom Speed Selection
This register sets the distance between motor control pulses to control zoom speed.
Address
: 0x0428
Data (7:0)
: 0x01 – minimum speed (GUI, SPD)
: 0xFF – maximum speed (GUI, SPD)
Data (31:8)
: N/A
4.5.1.5
Focus Travel Distance Selection
This register sets the number of motor control pulses to control focus travel distance.
Address
: 0x041C
Data (11:0)
: 0x001 – min travel distance (GUI, Near)
: 0xFFF – max travel distance (GUI, Far)
Data (23:16)
: 0x1 – Focus Near (slider/window #), (GUI, <)
: 0x2 – Focus Far (slider/window #), (GUI, >)
: 0x4 – Focus Near (full, 0xFFF pulses), (GUI, <<)
: 0x8 – Focus Far (full, 0xFFF pulses), (GUI, >>)
Data (15:12)
: N/A
Data (31:24)
: N/A
4.5.1.6
Focus Speed Selection
This register sets the distance between motor control pulses to control focus speed.
Address
: 0x0420
Data (7:0)
: 0x01 – minimum speed (GUI, SPD)
: 0xFF – maximum speed (GUI, SPD)
Data (31:8)
: N/A
4.5.1.2
Iris Travel Distance Selection
This register sets the number of motor control pulses to control iris travel distance.
Address
: 0x0414
Data (11:0)
: 0x001 – min travel distance (GUI, Close)
: 0xFFF – max travel distance (GUI, Open)