45
Chapter 8 - Diagnostics
DEFINITION OF DIAGNOSTIC FEATURES FOR ALL IMPAX
SYSTEMS
Getting Into Diagnostics:
Turn the
SUPERVISOR'S KEY
to the on or horizontal position. (Note if the IMPAX is
currently in a force or tolerance screen the Clear key will have to be pressed to get back to a
quantity screen.)
Press Function
(#)
. The display will show “SELECT FUNCTION”.
Press the number 4 key. (Function 4 selects the diagnostics mode.) The display will show
“
ACCESS
_”
.
Enter the access code by pressing the numbers 5, 6, 8, 6, then press Enter/Yes, the display will
show
“
REDEFINE?
”.
This is asking if you wish to redefine the access code from 5686 to a four
digit number of your choice.
If you answer no by pressing Next/No. The display will show “DIAGNOSTICS”
.
If you wish to
redefine the access code press Enter/Yes at the
“
REDEFINE
?”
prompt.
The IMPAX will ask
you for a NEW access code. Press any four digit number combination then press
Enter/Yes. The
display now shows “ACCESS
_”
. Press the same four digit code you just entered, then press
Enter/Yes. The display will now show
“DIAGNOSTICS”. You can exit the diagnostics mode at
any time by pressing Clear.
Diagnostic Functions:
Versions' 47.xx, 50.xx, and 57.xx:
Press the number 2 key the IMPAX will display the old communications parameters.
Press the
ENTER/YES
key to step through the various settings. These settings will have no
effect on the IMPAX operation since they are no longer used.
Versions' 48.xx and 58.xx:
Press the number 9
key. If the display shows
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
, there is nothing being
transmitted or received by the IMPAX unit via the IMPAXNET. If the display has characters on