![Impacts STREAMER S320RD Operating Manual Download Page 26](http://html1.mh-extra.com/html/impacts/streamer-s320rd/streamer-s320rd_operating-manual_2048485026.webp)
S320RD
Operating Manual
24
Check Coolant Level
The cooling system is a closed type. Never open the radiator cap! Doing so may induce
air into the cooling system and may cause overheating.
1. Check the level when the engine is cold (room or
atmospheric temperature).
2. Check coolant level only at the overflow reservoir (A).
The coolant level should be between the "H" (H) and
"L" (L) marks.
3. If the amount of coolant is insufficient, remove the cap
(B) from the reservoir and add coolant to the "H" mark.
When replenishing, add a pre-mixed solution of water
and anti-freeze of the same proportions as that already
in the system.
4. Reinstall the cap.
When the engine is hot, the coolant system is pressurized and the overflow reservoir
cap should be opened slowly until all pressure is released.
5.2 Refuelling
Before filling up or changing the gas tank, the machine must be safely parked. See Chapter 2.5.
• Fire Protection Measures:
When dealing with fuels and liquid gas, no smoking, naked flames,
or other sources of ignition are permitted within the vicinity of the tank. Signs indicating the risk
zone must be arranged to be clearly visible. Storage of highly flammable materials in this area
is not permitted. Functioning fire extinguishers must be available to hand in the filling area at
all times.
To prevent liquid gas burns, use only carbon dioxide dry extinguishers or carbon dioxide
gas extinguishers.
When changing the gas tank wear leather protective gloves. Liquid gas causes frostbite
wounds on exposed skin!
The gas tank may be changed only at the specified locations by trained and authorized
persons.
1. Park machine securely before changing (see Chapter 2.5)
2. Close shut-off valve (2) tightly (CW).
3. Start engine in neutral and run L.P. Gas system until empty.
4. Unscrew nut (3) with a suitable wrench (left hand thread!), holding with the handle (4).
5. Remove hose and immediately screw the valve cover cap onto the empty gas tank (1).
6. Release the strap (5) and remove the retainer (6).
Summary of Contents for STREAMER S320RD
Page 1: ...Operating Manual S320RD Your Partner for Mobile Surface Preparation IMPACTSAmericas com...
Page 53: ...Operating Manual S320RD 51 8 4 Circuit Diagrams...
Page 54: ...S320RD Operating Manual 52 Electric System...
Page 55: ...Operating Manual S320RD 53 Hydraulic System...
Page 57: ......
Page 58: ...S320RD Operating Manual 56 9 2 Diagnosis of Failures Filter Unit...
Page 59: ...Operating Manual S320RD 57 9 3 Diagnosis of Failures Motor...
Page 60: ...S320RD Operating Manual 58 9 4 Diagnosis of Failures Traction Drive...
Page 61: ...Operating Manual S320RD 59 9 5 Diagnosis of Failures Kawasaki Engine...
Page 62: ...S320RD Operating Manual 60 Kawasaki Engine...
Page 63: ...Operating Manual S320RD 61 Kawasaki Engine...
Page 64: ...S320RD Operating Manual 62 Kawasaki Engine...
Page 65: ...Operating Manual S320RD 63 Kawasaki Engine...
Page 66: ...S320RD Operating Manual 64 Kawasaki Engine...
Page 67: ......