ZONES/Zone 1/Settings
Menu item
Description
Range
Default
Customised
value
Function Mode (1)
Sets the zone 1 operating mode
OFF / MAN /
AUTO
MAN
Set AUTO Comfort (2)
Zone 1 room temperature correlated to the active time slots of the zone
1 calendar
10°C ÷ 35°C
20°C
Set AUTO reduced (2)
Zone 1 room temperature correlated to the NON active time slots of
the zone 1 program
5°C ÷ 30°C
16°C
Set MAN (3)
Zone 1 room temperature that can be activated by selecting the oper-
ating mode = manual
5°C ÷ 35°C
20°C
Weather comp. offset (4)
Zone 1 flow temperature correction in relation to external probe de-
tection
-9°C ÷ 9°C
0°C
Maximum heating set (5) Maximum zone 1 flow temperature
20°C ÷ 85°C
85°C
(1)
Not displayed
if remote device present
(2)
Not displayed
when:
- the “Operating mode” parameter is set to “Man” or “Off”;
- lack or unavailability of room and wireless probes;
(3)
Not displayed
when:
- the “Operating mode” parameter is set to “Auto” or “Off”;
- lack or unavailability of room and wireless probes;
(4)
Not displayed
when:
- the external probe is absent/unavailable
- a room probe is configured
- the “Operating mode” parameter is set to “Off”
- the remote device is present
(5)
Not displayed
when:
- the external probe is present
- a room probe is configured
- the “Operating mode” parameter is set to “Off”