Both the probe and the concentrator are suitable for indoor operation; they cannot be used outdoors and/or in environments 

subject to atmospheric agents.

Association procedure:

Insert the batteries on the probe and press the button on the probe for 5 sec.

If the probe is already previously associated, the LH and RH LEDs will flash alternately, therefore

it is necessary to proceed 

with the RF disassociation

(see RF Disassociation operations);

if it is

not associated

 the LH LED will start to flash (RH LED off), then continue with the next step of this procedure.

Zone assignment to wireless room probe:

1.  make sure to have correctly made the electrical connections between concentrator and boiler and to have inserted the batteries on the 

wireless probe;

2.  feed the boiler and access the Menu. For more details on menu navigation and access controls, see (Par. 2.6);

3.  access with the “Service” credentials;

4.  access the Zones Menu;

5.  select the zone to which the room probe refers;

6.  enter the Definition/Room probe menu;

7.  Select Type = RF;

8.  set the M3 address of the concentrator to which to associate the wireless probe (the M3 address is defined by the position of the switch-

es on the board inside the concentrator, default 0);

9.  press OK (a confirmation window will be displayed with the text "Confirm operation?");

10. accept the confirmation request by pressing OK; then the display will show "Status ..." (association in progress) and Lh LED will flash 

on the concentrator (pending association);

11. move to the probe to be associated within 30 seconds and press the central button for 5 seconds. When the LH LED flashes, briefly 

press the button again (1 second);

12. once the operation has been completed correctly, the 2 LH and RH LEDs will flash alternately on the probe for 10 sec. to then indicate 

on the LH LED the number of the associated zone by flashing, with the RH LED steady. If the operation is not completed correctly, the 

two LEDs will flash synchronously for 5 seconds and the display will show the text "Status No-Link" (the operation needs to be repeat-

ed);

13. on Display, when the operation is completed correctly, the room probe status appears as “OK”.

Indications displayed on the "Room probe - Status" menu

The following items appear in the Room probe association window:

Status =  Err:

 configuration error; the association sequence on the concentrator was not successful. Repeat the association sequence.

Status = No link:

 error on RF association between probe and concentrator; it may also appear with probe battery flat. Check wireless 

probe operation and repeat the association sequence.

Status = - - :

 indicates the wait for configuration; if it is maintained for a long time during the association sequence, check the connec-

tion between the concentrator and boiler.

Status = ... :

 indicates the mode of association in progress.

Status = ok:

  indicates the correct association between the wireless probe and the zone to be controlled.

RF disassociation on wireless room probe

Should it be necessary to reset a previous assignment made on the room probe, proceed with the following operation on the room probe:

1.  Press and hold the RF Probe button for at least 5s, if it is associated the LH-LEDs and the RH-LEDs will start to flash alternately;

2.  At this point, press the button again for 5s and release it when only the LH-LED starts flashing while the RH-LED remains off;

3.  Wait until the LH LED stops flashing before making a new association.

By using optional kits such as the concentrator kit for wireless room probes (if necessary to manage a single zone) and any wireless room 

probe kit (to manage any other zones up to a maximum of 3), it is possible to activate a room control in central heating / C.H. managed 

directly by the boiler.

The central heating / C.H. program will manage two room temperatures (comfort and reduced) in combination with the slots requested 

on the central heating / C.H. program (possibly diversified for the 3 zones).

Under these conditions, it will be possible to activate a system flow temperature modulating control so as to limit consumptions (enter 

any temperature control class, see table below).

To complete the room control via wireless probes, it is possible to connect the external probe (optional) and activate the control via the 

Dominus App (optional).

Remember that the central heating / C.H. demand, in addition to being subject to the central heating / C.H. program and to the tempera-

ture detected by the room probe, it will also be controlled by the contact set up for limit switch micro (terminals 40-41 for single zone).

Summary of Contents for VICTRIX ZEUS SUPERIOR 25

Page 1: ...Instructionsandrecommendations Installer User Maintenancetechnician 1 045260ENG 1 045260ENG IE VICTRIXZEUS SUPERIOR 25 30 35 ...

Page 2: ...tion 27 1 18 Separatorkitinstallation 30 1 19 C9adaptorkitinstallation 32 1 20 C15configurationconcentrickit 35 1 21 ConcentrickitC10configuration Ø80 125 36 1 22 ConfigurationC10 C12separatorkit Ø80 80 38 1 23 Ductingoffluesortechnicalslots 41 1 24 ConfigurationtypeB openchamberandfanassistedforindoors 42 1 25 Flueexhausttoflue chimney 42 1 26 Flues chimneysandchimneycaps 42 1 27 Watertreatmentpl...

Page 3: ...tion 88 3 14 Fluetest 88 3 15 Parametersandinformationmenu 90 3 16 Specificinformationforcorrectboilerinstallationincommonpressurisedfluesystems C10 C12 103 3 17 Boilercouplingwithwirelessroomprobes 103 3 18 Automaticventingfunction 105 3 19 Chimneysweep function 105 3 20 Screedheaterfunction 105 3 21 Pumpanti blockfunction 106 3 22 Three wayanti blocksystem 106 3 23 Radiatorsantifreezefunction 10...

Page 4: ...agescarefully youwillbeabletodrawusefultipsontheproperuseofthedevice compliancewithwhichwillconfirmyoursatisfactionwiththeImmergasproduct ThecompanyIMMERGASS p A withregisteredofficeinviaCisaLigure9542041Brescello RE declaresthatthedesign manufac turingandafter salesassistanceprocessescomplywiththerequirementsofstandardUNIENISO9001 2015 ForfurtherdetailsontheproductCEmarking requestacopyoftheDecla...

Page 5: ...eproductcarefullytoensureproper installation ThisinstructionsmanualprovidestechnicalinformationforinstallingImmergasproducts Asfortheotherissuesrelatedto the installation of products e g safety at the workplace environmental protection accident prevention it is necessary to complywiththeprovisionsofthestandardsinforceandtheprinciplesofgoodpractice AllImmergasproductsareprotectedwithsuitabletranspo...

Page 6: ...s WARNINGS Strictlyfollowalloftheindicationsnexttothepictogram Failuretofollowtheindicationscangeneratehazardsituations resultinginpossibleminorinjuriestothehealthofboththeoperatorandtheuseringeneral and orslightmaterialdamage ATTENTION Readandunderstandtheinstructionsoftheappliancebeforecarryingoutanyoperation carefullyfollowingtheinstruc tionsgiven Failuretoobservetheinstructionsmayresultinmalfu...

Page 7: ...acementofthosewithappliancesand orequivalentcomponents Thewallsurfacemustbesmooth withoutanyprotrusionsorrecessesenablingaccesstotherearpart Theyarenotdesignedto beinstalledonplinthsorfloors Fig 1 Byvaryingthetypeofinstallationtheclassificationoftheboileralsovaries precisely TypeB23 orB53 boilerifinstalledusingtherelevantterminalforairintakedirectlyfromtheroominwhichtheboilerhasbeen installed Type...

Page 8: ...appliance paper rags plastic polystyrene etc Do not place household appliances underneath the boiler as they could be damaged if the safety valve intervenes if the drain trapisblocked orifthereareleaksfromthehydraulicconnections otherwise themanufacturercannotbeheldresponsiblefor anydamagecausedtothehouseholdappliances Fortheaforementionedreasons werecommendnotplacingfurnishings furniture etc unde...

Page 9: ...uitableforinstallationonwallsmadeofcom bustiblematerial The installation of the boiler on the wall must guarantee a stable and effective support to the generatoritself The plugs standard supply are only to be used to fix the boiler to the wall they only ensure adequate support if inserted correctly ac cordingtotechnicalstandards inwallsmadeofsolidorsemi hollowbrickorblock Inthecaseofwallsmadefromh...

Page 10: ...atedraintrap Onfirstlightingoftheboiler fluegasmaycomeoutthecondensatedrain afterafewminutes operation check that this no longer occurs If this is the case the drain trap is correctly filled withcondensateuptoaheightthatdoesnotallowthefluegastopass TypeBopenchamberboilersmustnotbeinstalledinplaceswherecommercial artisanorin dustrial activities take place which use products that may develop volatil...

Page 11: ...11 Installer User Maintenance technician Technical Data Failuretocomplywiththeaboveimpliespersonalresponsibilityandinvalidatesthewarranty ...

Page 12: ...15 230 25 70 70 902 175 70 70 75 130 2 Key Fig 2 V Electricalconnection G Gassupply SC Condensatedrain minimuminter naldiameterØ13mm R Systemreturn M Systemflow RC Domestichotwaterpump optional AC Domestichotwateroutlet AF Domestichotwaterinlet Height mm Width mm Depth mm 900 600 450 TEMPLATECONNECTIONS GAS D H W SYSTEM G AC AF R M 1 2 1 2 1 2 3 4 3 4 ...

Page 13: ...theproperfunctioningoftheappliance Protectthecentralheatingcircuitfromfreezingbyinsertingagood qualityantifreezeliquidintothiscircuit whichisespeciallysuit edforcentralheatingsystemsandwhichismanufacturerguaranteednottocausedamagetotheheatexchangerorothercomponents oftheboiler Theantifreezeliquidmustnotbeharmfultoone shealth Theinstructionsofthemanufacturerofthisliquidmustbefol lowedscrupulouslyre...

Page 14: ...lcomponentsoftheboilerarenotfaulty Thewarrantydoesnotcoverdamageduetointerruptionoftheelectricalpowersupplyandfailuretocomplywiththatstatedonthepre viouspage Iftheboilerisinstalledinplaceswherethetemperaturefallsbelow0 Cthedomestichotwaterandcentralheatingattachment pipesandthecondensatedrainpipemustbeinsulated Thefreezingprotectionsystemsdescribedinthischapterareinstalledonlyfortheprotectionofthe...

Page 15: ...d seeboilerdatanameplate Ifdifferent theboilermustbeconvertedforoperationwiththeothertypeofgas seeconvertingapplianceforothergastypes Itisalsoimportanttocheckthedynamicpressureofthemains methaneorLPG usedtosup ply the boiler which must comply with EN 437 and its attachment as insufficient levels may reducegeneratoroutputandcausediscomforttotheuser Static dynamicnetworkpressureshigherthanthoserequi...

Page 16: ...st13mm Thesystemconnectingtheappliancetothedrainagesystemmustbecarriedoutinsuchawayastopreventocclusionandfreezingofthe liquidcontainedinit Beforeapplianceignition ensurethatthecondensatecanbecorrectlyremoved Afterfirstignition checkthatthedraintrapisfilledwith condensate Also complywithnationalandlocalregulationsondischargingwastewaters Intheeventcondensateisnotdischargedintothewastewaterdrainage...

Page 17: ...entheconnectionscompartmentasfollows 1 Removethefrontpanel Fig 64 65 2 Loosenthescrews a 3 Removethecover b fromthecontrolpanel c a a b c 1 1 1 2 a 5 Atthispoint youcanaccesstheterminalboard Alsoensurethattheelectricalinstallationcorrespondstomaximumabsorbedpowerspecificationsasshownontheboilerdataname plate Theboilersaresuppliedcompletewitha Y typeH 05 VVF3 x 0 75 mm2 powersupplycable withoutplug...

Page 18: ...ControlDevice V2 CARV2 withclimatechrono thermostatfunction In addition to the functions described in the previous point the CARV2 panel enables the user to control all the important information regardingoperationoftheapplianceandtheheatingsystemwiththeopportunitytoeasilyinterveneonthepreviouslysetparameters withouthavingtogotowheretheapplianceisinstalled Thepanelisprovidedwithself diagnosistodisp...

Page 19: ...tirelyandsolelyviatheboiler set boost anti legionellamanagement Thistypeofdialogueisrecommendedforcommercialremotedevices otherthanCARV2 Theremotecontrolwillremainincontrolof the Operatingmode SetCentralheating C H and Centralheating C H demand 1 10 EXTERNALTEMPERATUREPROBE OPTIONAL Theboilerisdesignedfortheapplicationoftheexternaltemperatureprobe Fig 7 whichisavailableasanoptionalkit Refertothere...

Page 20: ...ecanbesetontheboilerparametermenu Tovarythemaximumincreasevalue accesstheMenuwith Service credentialstopath Service CentralHeating Editmaxcommonflowpr Thisparametersettingcanvaryfrom5to15 C default5 C Onthedisplay thecentraldigitswillalwaysshowtheboileroutlettemperature Withflowprobeincorrection itwillbehigherthantherequiredcentralheating C H set 1 12 TEMPERATURECONTROLSETTING Bysettingtheparamete...

Page 21: ...thasaResistanceFactorbasedonexperimentaltestsandspecifiedinthetablebelow TheResistanceFactorforindividualcomponentsisindependentfromthetypeofboileronwhichitisinstalledandhasadimensionless size Itishowever conditionedbythetemperatureofthefluidsthatpassthroughthepipeandtherefore variesaccordingtoapplicationsfor airintakeorflueexhaust Eachsinglecomponenthasaresistancecorrespondingtoacertainlengthinme...

Page 22: ...aching inparticular theflueexhaustductinthe Ø80 separator kit configuration If the condition described above is not adequately guaran teed itwillbenecessarytousetheappropriateretainingclampkit When installing horizontal pipes a minimum inclination of 1 5 towards the boiler must be maintained and a section clip withpinmustbeinstalledevery3metres AllboilershaveanexperimentallyobtainablemaximumResist...

Page 23: ...Intakem 16 3 m 2 5 Intakem 18 7 Exhaustm 4 9 m 7 7 Exhaustm 16 3 Exhaustm 13 6 Concentricvertical intake exhaustterminal Ø 60 100 Intakem 9 m 1 4 Intakem 10 3 Exhaustm 2 7 m 4 3 Exhaustm 9 Exhaustm 7 5 PipeØ 80m 1 Intakem 0 87 m 0 1 Intakem 1 0 Exhaustm 0 4 m 0 4 Exhaustm 1 2 m 0 2 Exhaustm 1 0 m 0 5 Completeintake terminalØ 80m 1 Intakem 3 m 0 5 Intakem 3 4 Exhaustm 0 9 m 1 4 IntaketerminalØ 80 E...

Page 24: ...rewsprovided Installtheuppercover fixingitusingthe4screwspresentinthekit positioningtherelevantgaskets Engagethe90 Ø80bendwiththemaleend smooth inthefemaleend withlipseal oftheØ80flangeunittotheendstop Introducethe gasket makingitrunalongthebend Fixitusingthemetalsheetplateandtightenbymeansoftheclipspresentinthekit makingsureto blockthe4gasketflaps Fit the male end smooth of the exhaust pipe into ...

Page 25: ...2 13 Thecoverkitincludes Fig 13 N 1 Thermoformedcover N 1 Gasketclampingplate N 1 Gasket N 1 Gaskettighteningclip N 1 Flangeplatewithsamplepoints Theterminalkitincludes Fig 13 N 1 Gasket N 1 ExhaustflangeØ80 N 1 Ø8090 bend N 1 ExhaustpipeØ80 N 1 Wallsealingplate ...

Page 26: ...minalisrespectedoninstallation Mountingthehorizontalintake exhaustkitØ 60 100 Fig 14 1 Install the bend with flange 2 on the central hole of the boiler positioning gasket 1 with the circular projections downwards in contactwiththeboilerflange andtightenusingthescrewspresentinthekit 2 FittheØ60 100 3 concentricterminalpipewiththemaleside smooth tothefemalesideofthebend 2 uptotheendstop making suret...

Page 27: ...terØ 80 125 2 TheKitØ80 125includes Fig 16 N 1 ConcentricbendØ 80 125at87 3 N 1 Int exhaustconcentricterminalØ 80 125 4 N 1 Internalwallsealingplate 5 N 1 Externalwallsealingplate 6 Theremainingkitcomponentsmustnotbeused ExtensionsforØ80 125horizontalkit Kitassembly Fig 17 Thekitwiththisconfigurationcanbeextendeduptoamax lengthof32m includingtheterminalwithgridandexcludingtheconcen tricbendleaving...

Page 28: ...e 2 uptotheendstop makingsurethatthe wallsealingplatehasbeenfitted 3 thiswillensuresealingandjoiningoftheelementsmakingupthekit Whentheboilerisinstalledinareaswhereverycoldtemperaturescanbereached aspecialanti freezekitisavailablethatcan beinstalledasanalternativetothestandardkit C33 7 4 6 5 1 2 3 18 Thekitincludes Fig 18 N 1 Gasket 1 N 1 Femaleconcentricflange 2 N 1 Wallsealingplate 3 N 1 Alumini...

Page 29: ...ealuminiumsheet 4 shapingittoensurethatrainwaterrunsoff 4 Positionthefixedhalf shell 5 onthealuminiumtile 5 Inserttheintake exhaustterminal 7 6 FittheØ80 125concentricterminalpipewiththemaleside smooth tothefemalesideoftheadapter 1 withlipseals uptotheend stop makingsurethatthewallsealingplate 3 hasbeenfitted thiswillensuresealingandjoiningoftheelementsmakingupthekit C33 1 2 3 4 5 6 7 20 Theadapte...

Page 30: ...rontherightorlefthandsideofthecentralexhaustpipe S Bothductscanberoutedinanydirection MountingtheseparatorkitØ 80 80 Fig 22 1 Installtheflange 4 onthecentralholeoftheboiler positioninggasket 1 withthecircularprojectionsdownwardsincontactwith theboilerflange 2 Tightenwiththehexagonalheadandflatpointscrewsprovidedinthekit 3 Replacetheflatflangepresentinthelateralholewithrespecttothecentralone accord...

Page 31: ...nces Fig 23 The minimum installation clearance measurements of the Ø 80 80separatorterminalkithavebeenstatedinsomelimitcondi tions C43 23 ExtensionsforseparatorkitØ 80 80 Themaximumverticalstraightlength withoutbends thatcanbeusedforØ80intakeandexhaustpipesis41metres regardlessfrom whethertheyareusedforintakeorexhaust Themaximumhorizontalstraightlength withbendinsuctionandinexhaust thatcanbeusedfo...

Page 32: ...ialtalc To favour the removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a minimum slopeof1 5 Fig 24 1 Mountthecomponentsofkit C9 onthedoor A oftheductingsystem Fig 26 2 VersionØ125only mounttheflangedadaptor 11 interposingtheconcentricgasket 10 ontheboiler fittingitwiththescrews 12 3 Mounttheductingsystemasdescribedintherelativeinstructionssheet 4 Ca...

Page 33: ...allofthesmokeductandtheinnerwalloftheshaft 30 mm forcircularsectionshaftsand20 mmintheeventofasquaresectionshaft Fig 25 Maximum 2 changes of direction are allowed on the vertical section of the flue system with a maximum clearance angle of 30 with re specttothevertical ThemaximumverticalextensionusingaØ 60ductingsystemis22 m themaximumextensionincludes1bendØ 60 100at90 1 mof horizontalpipeØ 60 100...

Page 34: ...34 Installer User Maintenance technician Technical Data C93 X 27 ...

Page 35: ...cular it must ensure that the degree of recirculationofthefluegasisalwaysbelow10 The common supply shaft must be sized so that in combination withtheintakepartoftheroofterminal avacuumgreaterthan5 Paisnotgeneratedatthepointoftheshaftwheretheboilerdraws the combustion air from the shaft itself when the boiler works at maximum heat output and the entire multiple ducting system worksatmaximumdesignpo...

Page 36: ... ConcentrickitassemblyinC10 typeconfiguration Fig 31 To favour the removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a minimum slopeof1 5 Fig 30 1 Mounttheflangedadaptor 14 interposingtheconcentricgasket 15 ontheboiler fittingitwiththescrews 13 2 Insertthenon returnvalvekitonfluegasØ 80intheflangedadapter takingcaretoremovethespacerØ 80th 5mm Makesur...

Page 37: ...3 4 5 6 7 6 8 9 A 15 14 13 12 10 11 31 Key Fig 31 TheC9adaptorkitincludes No 1 DooradaptorØ 100orØ 125 1 No 1 Doorgasketmadeofneoprene 2 No 4 Screws4 2x9ST 3 No 1 HexheadedscrewM6x20 4 No 1 FlatnylonwasherM6 5 No 2 Doorholeclosuremetal sheetplateplug 6 No 1 Pluggasketmadeofneoprene 7 No 1 ToothedwasherM6 8 No 1 M6nut 9 TheØ 80 125extensionpipekitincludes No 1 ExtensionpipeunitØ 80 125 10 Thebendki...

Page 38: ...heninsertthenon returnvalveonthefluegasØ 80 2 Remove the flat flange present in the intake hole and replace it with the intake flange 3 positioning the gasket 2 contained in the separatorkitØ 80 80andtightenusingthesuppliedself threadingscrews 3 Fitthebendswithmaleside smooth 5 inthefemalesideoftheflanges 3and4 4 Fortheintakefromshaft C10 orfromacommonintakeduct connecttheØ 80intakeducts 6 tothebe...

Page 39: ...gegasket 2 No 1 Femaleintakeflange 3 No 1 Femaleexhaustflange 4 No 2 Bend90 Ø80 5 No 1 ExtensionØ80 6 C10only No 1 IntaketerminalØ80 6 C12only No 2 Internalwallsealingplates 7 1 Externalwallsealingplate 8 C12only No 1 ExhaustpipeØ80 9 No 1 fluegasnon returnvalvekitØ 80 10 N B eliminatetheextensionØ 125 Theconfigurationonwallsoppositethebuildingisnotallowed C10 35 ...

Page 40: ...pecifications with which it was de signed themaximumpressure whenn 1boilerisworkingatmaximumheatinput withn numberoftotalboilersconnectedorthatcanbe connectedtothesamecollectiveduct andaboilerworksatminimumheatinput is25Pa fluegasmassatmaximumheatinput fluegasmassatminimumheatinput theminimumpressuredifferenceallowedbetweenthecombustionproductoutletandthecombustionairinletis 200Pa 400Pafor C12 inc...

Page 41: ...tainedinthestandardandincurrenttechnicalregulations inparticular thedeclarationofconformitymustbecompiledattheendofworkandoncommissioningoftheductedsystem Theinstructionsintheprojectortechnicalreportmustlikewisebefollowed incasesprovidedforbythestandardandcurrenttechnical regulations Toguaranteereliabilityandoperationovertimeoftheductingsystem makesure it is used in average atmospheric and environ...

Page 42: ...ondensation havingnom inalheatinputsthatdonotdifferbymorethan30 lesswithrespecttothemaximumthatcanbeattachedandpoweredbythesamefuel Thethermo fluiddynamicfeatures flueflowrate ofcarbondioxide humidityetc oftheappliancesattachedtothesamemultiple fluesorcombinedflues mustnotdifferbymorethan10 withrespecttotheaverageboilerattached Multipleandcombinedfluesmustbespeciallydesignedaccordingtothecalculati...

Page 43: ...aust is allowed for natural draughtorfanassistedgasapplianceswithaheatinputrangefrom4to35 kW providedtheconditionsasperthecurrenttechnicalstand ardsarerespected 1 27 WATERTREATMENTPLANTFILLING Asalreadymentionedinthepreviousparagraphs atreatmentofthethermalanddomesticsystemwaterisrequired incompliancewith thelocalstandardsinforce Theparametersthatinfluencethedurationandproperoperationoftheheatexch...

Page 44: ...utalsoservesasprotectionagainstcorrosion Insertasuitableinhibitor passivator forexampleSentinelX100 FernoxProtectorF1 orJenaqua100 ifrequired alsoinsertappro priateantifreeze suchasforexampleSentinelX500 FernoxAlphi11orJenaqua500 Checkelectricalconductionofthewater whichshouldbehigherthan2000µs cminthecaseoftreatedwaterandlowerthan600µs cm inthecaseofnon treatedwater Topreventcorrosion thewatersys...

Page 45: ...formedbyqualifiedpersonnelandinthepresenceofstaffonly 1 checkthattheinternalsystemisproperlysealedaccordingtothespecificationssetforthbyregulationsinforce 2 Ensurethatthetypeofgasusedcorrespondstotheboilersettings thetypeofgasappearsonthedisplayonfirstelectricalpowersup ply 3 checkthatthereisnoairinthegaspipe 4 checkconnectiontoa230V 50Hzpowermains correctL Npolarityandtheearthingconnection 5 chec...

Page 46: ...ers Maximum speed and Minimum speed at the same value the pump operates at constant speed Fortheboilertoworkproperly itisnotallowedtodropbelowtheminimumspeedvalue 6 Indomestichotwatermode thecirculatorpumpalwaysrunsatfullspeed PumpLED TheLEDflashesgreenwhenthepumpispoweredandthepwmcontrolsignalisconnected The LED lights up steady green when the pump is powered and the signal cable disconnected In ...

Page 47: ...emotor BypassAdjustment Parag 1 34 Theboilerleavesthefactorywiththebypassopen Ifnecessary theby passcanberegulatedtosystemrequirementsfromminimum by passclosed tomaximum by passopen Adjustusingaflatheadscrewdriver turnclockwiseandopentheby pass anticlockwiseitisclosed The bypass ensures minimum circulation of the water in the boiler and correct operation of the appliance in case of systems withshu...

Page 48: ...ilabletotheVictrixZeusSuperior30 35system A C D B v9 v9 v6 X1 Y1 Y2 42 Key Fig 41 42 A B Headavailablewithbypassclosed B Headavailablewithbypassopen C D Powerabsorbedbythepumpwithbypassclosed dottedarea D Powerabsorbedbythepumpwithby passopen dottedarea Key Fig 41 42 X1 Flowrate l h Y1 Head kPa Y2 Powerabsorbedbypump W v6 Speed6 v9 Speed9 ...

Page 49: ...lerispreparedforapplicationofthepolyphosphatedispenserkit Thisisatypeofchemicalconditioningtreatmentfordomestichotwater ifprovidedforbycurrentregulations Cycloidalfilterkit onrequest Themagneticcycloidalfilterisabletodetecttheferrousresiduespresentinthesystem swater Thanks tothetwococksinthekit itfacilitatesmaintenancebycleaningthefilterwithouthavingtoemptythecircuit Theabove mentionedkitsaresuppl...

Page 50: ...p 8 Absolutepressureswitch 9 Doubleflowprobe 10 Non returnvalveonfluegas 11 Airintakepipe 12 Gasmanifold 13 Doubleflueprobesensor 14 Fluehoodwithsamplepoints airA fluegasF 15 Domestichotwaterexpansionvessel 16 Systemexpansionvessel 17 Heatexchanger 18 Burner 19 Ignition detectionelectrode 20 Fan 21 Gasmixer 22 Gasdiaphragm 23 D H W probe 24 Airventvalve 25 Stainlesssteelstoragetank 26 Returnprobe ...

Page 51: ...ttheairintake flueexhaustterminals iffitted arenotblocked Iftemporaryshutdownoftheboilerisrequired proceedasfollows a draintheheatingsystemifantifreezeisnotused b shut offallelectrical waterandgassupplies Inthecaseofworkormaintenancetostructureslocatedinthevicinityofductingordevicesforflueextractionandrelativeac cessories switch off the appliance and on completion of operations ensure that a quali...

Page 52: ...meterinterceptiondeviceorthemaininterceptiondevice ifpossible closethegasinterceptioncockontheproduct ifpossible opendoorsandwindowswideandcreateanaircurrent donotuseopenflames e g lighters matches donotsmoke donotuseelectricalswitches plugs doorbells telephonesorintercomdevicesinthebuild ing callanauthorisedcompany e g AuthorisedTechnicalAssistanceCentre ifyousmellburningorseesmokecomingoutofthea...

Page 53: ...esc resetbutton 20 SetDHW Domestichotwater Knob 2 4 BOILERUSE Beforeignitionmakesuretheheatingsystemisfilledwithwaterandthatthemanometer 7 indicatesapressureof1 1 2bar Thefollowingaredisplayeduponignition Typeofpanel Panelfirmwareversion Boardfirmwareversion Typeofselectedgas Oncethedevicehasbeenpowered itgoesintothestatuspriortoswitch off Pressthe MODE buttontocyclicallyselectthedesiredop erating...

Page 54: ...sabled Disabled Disabled Summer Enabled Disabled Activated Winter Enabled Enabled Activated Stand by Disabled Disabled Activated 45 2 5 OPERATINGMODE Theboilercanworkinthefollowingmodes OFF STAND BY SUMMER WINTER Iftheboilerisat OFF pressthebutton toactivateit Ifthisisnotthecase gotothenextpoint Thenpressthe MODE buttoninsequencetosetthesystemtostand by summer orwinter position OFF mode In Stand b...

Page 55: ...previously Oncethemenuitemtobesetisreached press OK orrotatethe SetCentralheating C H knobtohighlightthevaluetobechanged Changethevaluebyturningthe Setcentralheating C H knob Confirmingachange Attheendofthemodification press OK toconfirmthechangeandgobacktothepreviouslyselectedmenuitem Exitwithoutsaving Ifattheendofthemodificationyoupress RESET youwillreturntothepreviouslyselectedmenuitemwithoutco...

Page 56: ...areassignedtoZone1 Zone 2 ifpresent Zone3 ifpresent You can assign the calendar to a single day or to a group of days single day Monday Friday Saturday Sunday Monday Saturday Monday Sunday Thereforeeachdaymaybepersonalisedwith4differentoperatingprograms Forconvenientselection thebottompartdisplaysthegraphicsoftherelevantcalendarbeingselected Fig 48 IMPOSTA DATA E ORA Zone 1 program Day s Calendar ...

Page 57: ...ater temperatureischangedin Auto automaticoperation the SetDHW Domestichotwater knob activatesthetimedmanualoperation Inthismode theDHW Domestichotwater temperatureisregulatedtothevaluesetuntilthe nextbandchangeoftheprogrammedDHW Domestichotwater program Theforcedautomaticfunctioncanbeinterruptedbysim plypressingthe MODE button BoostFunction ItisalsopossibleforDomestichotwater D H W tosetthe Boost...

Page 58: ...rebeforeanyuse Usewithwirelessroomprobes Optional UsingCentralheating C H throughthewirelessroomprobesistheoptimalsolutionforcontrollingtheroomtemperature Withroomprobesconfiguredandenabled itwillbepossibletosetontheindividualzonestheroomtemperaturewithwhichto controlthecentralheating C H ignition thecentralheating C H flowsetatwhichtheboilerwilloperatewillberegulatedto theidealtemperatureformaint...

Page 59: ...ensors it is possible to select the zone operating mode Manual and set the minimum room set in these conditions the probe flow produces a central heating C H request permanent24h withminimumflowset Boilerflowtemperaturewithwirelessroomprobe Byactivatingthe Roomprobemodul function theboilerwillautomaticallymanagetheflowtemperaturemakingitcorrelatedtothe actualroomneed Theboilerflowtemperaturewillva...

Page 60: ...llbepossibletochoosethezoneofinterestandselectthesizetobevaried bothflowtemperatureandroomtem perature Adjustmentofthecentralheatingsystemflowtemperature Theflowtemperaturewillonlybeactivatedwhenthecentralheating C H requestispresent The system will ask the boiler for a radiator flow temperature capable of satisfying the maximum request as the room warms up theboilerwillalsoadaptbyloweringtheradia...

Page 61: ...ng Ifroomprobesarepresent Roomtemperature appearsdisplayingthereadingofthezoneroomtemperature Ifroomprobesarepresent RoomSet appears showingtheroomsetinprogress Zonemenudescription Information Operationstatus OFF off A ECO meansthatthezoneisinthetimeslotwherethecentralheating C H hasbeenprogrammedtobedeactivated A COMF meansthatthezoneisinthetimeslotwherethecentralheating C H hasbeenprogrammedtobe...

Page 62: ...rature TemperaturereadbytheDHWprobe Boostfunction SetstheDHW Domestichotwater boostfunctionmanagement Off On Auto Off Boost Off alwaysoff ON alwayson Auto managed as required by the DHW Domestic hot water pro gram Setmanagement SetstheDHW Domestichotwater setcontrolmode Auto Man Man Auto the DHW Domestic hot water set will be controlled at two levels accordingtotheDHW Domestichotwater program Manu...

Page 63: ...esthatenableyoutocustomiseuseofthezones Hereunderisalistofavailablemenus ZONE Menuitem Description Zone1 Definestheoperatingparameterstomanagezone1 ortheentiresystemifsingle zone Zone2 Definestheoperatingparameterstomanagethezone2 ifpresent Zone3 Definestheoperatingparameterstomanagethezone3 ifpresent ifpresent ...

Page 64: ...1 Open Close SetCH Thisdisplaysthezone1flowset 25 C 85 C Plant Informationrelatedtothetypeandpresenceorabsenceofaroomprobe Zone1InformationMenuisalwayspresentregardlessofwhetherornotaCARV2 isconnected notdisplayedwhenthe Req withroomprobe issettoNO displayedwhenthezoneofinterestisassociatedwitharoomprobe RFprobe ZONES Zone1 Information Plant Menuitem Description Range Roomprobe Thisdisplaysornotth...

Page 65: ...ual 5 C 35 C 20 C Weathercomp offset 4 Zone 1 flow temperature correction in relation to external probe de tection 9 C 9 C 0 C Maximumheatingset 5 Maximumzone1flowtemperature 20 C 85 C 85 C 1 Notdisplayedifremotedevicepresent 2 Notdisplayedwhen the Operatingmode parameterissetto Man or Off lackorunavailabilityofroomandwirelessprobes 3 Notdisplayedwhen the Operatingmode parameterissetto Auto or Off...

Page 66: ...edisplayoperatingmodeandtoaccessthepassword protectedmenus dedicatedtoaqualifiedtechnician MENU Timeandprogram Menuitem Description Range Default Customised value Dateandtime Currentdateandtimesetting AutoswitchtoDST Automaticallysetssummertime Yes No Yes Calendars DefinesthetimerangeforoperationinComfortandEconomymode Zone1program Zone1timescheduling CAL3 Zone2program Zone2timescheduling ifpresen...

Page 67: ...snotdisplayed Mainboardrev SW Boilerboardswversiondisplay Firmwareversion Displayboardswversiondisplay MENU Historicalalarmcode Menuitem Description Showalarm Thisdisplaystheboileranomalyhistory Thesizeoftheanomalyhistoryisequalto10anomalies MENU Generalsettings Menuitem Description Range Default Customised value Language Definestheremotepaneloperationlanguage ITA Display It is possible to adjust ...

Page 68: ...ects a fault on the gas valve supply Check its connection theanomalyisdetectedanddisplayedonlyin theeventofarequest PresstheResetbutton 1 05 Deliveryprobefault TheboarddetectsananomalyontheflowNTCprobe Theboilerdoesnotstart 1 07 Chimneysweep function Theboilerisinchimneysweepoperation 3 08 MaximumN ofresets Numberofallowedresetsalreadyperformed Theanomalycanbereset5times consecutively afterwhichth...

Page 69: ... if communication between the boiler and the remote controlislostorincorrectconnectiontotheterminals Disconnectandreconnectthepower totheboiler IftheRemoteControlis stillnotdetectedonre starting the boilerwillswitchtolocaloperating mode i e usingthecontrolsonthe controlpanel Checkthecorrect connectiontotheterminals 1 36 IMGBus communicationloss Communicationbetweenthevariouscomponentsisinter rupte...

Page 70: ...nterventionofDIM v2safetythermostat orLowtemperature safetythermostat outsidetheboiler During normal operation if an anomaly causes excessive overheating of the flow temperature in low temperature conditions theboilerblocks Inthiscase aftersuitablecooling itis possibletoresetthethermostat see relativeinstructionssheet 1 47 Burnerpower limitation Shouldfluehightemperaturebedetected theboilerreduc e...

Page 71: ... Itmayoccurin the event the P C B is replaced or if the parameters are al teredintheair gassection thusrequiring completecali bration Theboilerdoesnotstart 1 72 Fastcalibration required TheP C B detectsthatsomeparametershavebeenaltered thusrequiring fastcalibration Theboilerdoesnotstart 1 73 Highdeviation betweenflowprobe andsafetyflowprobe Faultyflowsensorornotcorrectlyinserted Ifnormalconditions...

Page 72: ...sence of flue gas recircula tion wind unstable gas pressure unstable fan speed or duetosystemmalfunction Theboilerkeepsworking 1 2 90 Combustionsignal beyondlimit The combustion signal is beyond the adjustment range re quiredforanextendedperiodoftime Theboilerkeepsworking 1 2 91 Incorrectignition block Theboardhasexhaustedallpossibleactionsinordertoob tainoptimalignitionoftheburner PresstheResetbu...

Page 73: ...ncentrator Checkreceiver sensorpositioning Checkprobebattery 1 122 Zone2deviceoffline alarm Lowqualityornoradiocommunicationbetweenthezone 2wirelessprobeandtheconcentrator Checkreceiver sensorpositioning Checkprobebattery 1 123 Zone3deviceoffline alarm Lowqualityornoradiocommunicationbetweenthezone 3wirelessprobeandtheconcentrator Checkreceiver sensorpositioning Checkprobebattery 1 125 Zone1room t...

Page 74: ... between concen tratorwithaddress 0 andboiler Checkconcentrator boiler display boardconnectionwiring Checkcorrectassociation Replaceconcentratorboardordisplay board 1 301 RFaddress1 concentratoroff line alarm Lack of communication on BUS wires between concen tratorwithaddress 1 andboiler Checkconcentrator boiler display boardconnectionwiring Checkcorrectassociation Replaceconcentratorboardordispla...

Page 75: ...eved oraskforassistancefromprofessionallyqualifiedpersonnel 5 Intheeventoffrequentpressuredrops contactqualifiedstaffforassistancetoeliminatethepossiblesystemleakage Bottomview 1 2 3 4 5 50 Key Fig 50 1 Systemfillingvalve 2 Systemdrainingvalve 3 GAScock 4 Storagetankdrainingvalve 5 Coldwaterinletcock 2 10 DRAININGTHESYSTEM Todraintheboiler usethespecialdrainingvalve Fig 50 Beforedraining ensuretha...

Page 76: ...llinformationrelativetotheantifreezeprotectionisstatedin Parag 1 4 2 14 PROLONGEDINACTIVITY Incaseofprolongedinactivity e g secondhome werecommend 1 toswitchoffthepowersupply 2 tocompletelyemptytheheatingcircuitandtheboilerD H W circuit Insystemsthataredrainedfrequently fillingmustbecarried outwithsuitablytreatedwatertoeliminatehardnessthatcancauselime scale 2 15 CLEANINGTHECASE 1 Usedampclothsand...

Page 77: ...boiler ensurethatthetypeofgasusedcorrespondstotheboilersettings thetypeofgasappearsonthedisplayonfirstelectricalpowersupply onthedatanameplateor withthedisplayalreadyon withthefollowingsequence MENU Information Ok checkconnectiontoa230V 50Hzpowermains correctL Npolarityandtheearthingconnection makesurethecentralheatingsystemisfilledwithwaterandthattheboilermanometerindicatesapressureof1 1 2bar swi...

Page 78: ...theirstateofwear Checkthattheburnerisintact thatithasnodeformationsorcutsandthatitisproperlyfixedtothecombustionchamberlid otherwise itmustbereplaced Visuallycheckthatthewatersafetydrainvalveisnotblocked Checkthat afterdischargingthesystempressureandbringingittozero readonboilerpressuregauge theexpansionvesselpressure isat1 0bar Checkthatthesystemstaticpressure withsystemcoldandafterrefillingthesy...

Page 79: ... 8 8 0 5 8 8 0 5 8 8 0 5 G31 10 5 0 5 10 3 0 5 10 3 0 5 Gastype O2 atNominalQ O2 atIgnitionQ O2 atMinimumQ G20 5 2 0 9 5 2 0 9 5 2 0 9 G31 5 2 0 7 5 2 0 7 5 2 0 7 VictrixZeusSuperior35 Gastype CO2 tonominalQ CO2 toignitionQ CO2 tominimumQ G20 8 8 0 5 8 8 0 5 8 8 0 5 G31 10 3 0 5 10 3 0 5 10 3 0 5 Gastype O2 atNominalQ O2 atIgnitionQ O2 atMinimumQ G20 5 2 0 9 5 2 0 9 5 2 0 9 G31 5 2 0 7 5 2 0 7 5 2...

Page 80: ...int 14 Airsamplepoint 15 Burner 16 Air gasmanifold 17 Non returnvalveonfluegas 18 Airintakepipe 19 Flowprobes 20 Airventvalve 21 Boilercirculatingpump 22 Systempressureswitch 23 Stainlesssteelstoragetank 24 Magnesiumanode 25 3 wayvalve motorised 26 Domestichotwaterexpansionvessel 27 D H W probe 28 Stainlesssteelcoilforstoragetank 29 8barsafetyvalve 30 Coldwaterinletnon returnvalve 31 Storagetankdr...

Page 81: ... X40 Roomthermostatjumper X70 Safety thermostat low tempera ture jumper Y1 Gasvalve Colourcodekey Fig 52 BK Black BL Blue BR Brown G Green GY Grey OR Orange P Purple PK Pink R Red W White Y Yellow AnyroomthermostatorON OFFmustbe connected to terminals 40 and 41 elimi natingjumperX40 Any CARV2 must be connected to termi nals44and41complyingwiththepolarity withouteliminatingjumperX40 Key Fig 52 1 23...

Page 82: ...ance 53 Key Fig 53 1 Fuse3 15quick250V 2 Greyremovablememory A19 Displayboard Thedisplayboardisequippedwitharemovablememory Ref 1Fig 54 whichrecordsalloperationparametersandcustomisationsofthe display wirelessprobes Dominusandtimermaintenance Shouldthedisplayboardbereplaced youcanusethememoryofthereplacedboardagainsoitisnotnecessarytoreconfiguretheappli ance 54 Key Fig 54 1 Blackremovablememory A1...

Page 83: ...erialblockingtheflowof condensate Abnormalnoisesinthe system Airinthesystem Checktheopeningofthecapoftheairventvalve Par 1 34 Makesure thesystempressureandexpansionvesselpre chargevaluesarewithin thesetlimits Thefactory setpressurevaluesoftheexpansionvessel mustbe1 0bar thevalueofsystempressuremustbebetween1and1 2 bar Poorproductionof D H W DHWheatexchangerclogged ContacttheAuthorisedAfter SalesAs...

Page 84: ...mbustionchamber theburnerflameisnottoohighorlowandthatitisstable doesnotdetachfromburner Maintenanceoperationsmustbecarriedoutbyanauthorisedcompany e g AuthorisedAfter SalesTechnicalAssistanceCen tre Riskofmaterialdamageafterusingspraysandliquidstosearchforleaks LeakspraysandliquidsclogthereferenceholeP Ref Fig 55 ofthegasvalve damagingitirreparably Duringinstallationandmaintenance donotusesprayor...

Page 85: ...ocedureinvolvesvariousstages nominalheatoutputcalibration intermediateheatoutputignitioncalibration minimumheatoutputcalibration ThecompletecalibrationfunctionoffersamaximumtimeofstaywithintheCalibrationMenuof20minutescountedafterthelastaction onthedisplaykeyboard Afterthistime thefunctionends showingthemessage Completecalibration The Calibration completed window will be automatically abandoned af...

Page 86: ...Par 4 2 editthevalueasdescribedintheparagraph Par 3 12 Whenthecombustionvaluemeasuredonthenominalpoweriscorrect requesttheadvancementoftheproceduretothenextphase in termediateignitionpower bypressingthe OK button CalibrationPhasemaxok Ignitionintermediateheatoutput Once the nominal heat output calibration is confirmed the boiler is calibrated with the intermediate heat output or ignition heat out ...

Page 87: ...n ok 59 IftheCo2valueisnotthatindicatedinthetable Par 4 2 editthevalueasdescribedintheparagraph Par 3 12 When the combustion value measured on the minimum power is correct request the end of the procedure by pressing the OK Cali brationPhaseminok button Theendofthefunctionisaccompaniedbythewindow Completecalibration 3 12 CO2REGULATION Duringthecompletecalibration Par 3 11 itispossibletomodifytheCO...

Page 88: ...functionisactive theboilersequentiallycarriesouttheproceduresrequiredtocalibratetheappliancewiththenominal inter mediateandminimumheatoutputvalues Fast calibration Calibration Phase Combustion Set Power perc CH temperature 0 26 C Flame Off Central Heating active max 61 CalibrationPhase indicatesthephaseofcalibrationinprogressandthestabilityconnectiononthecombustion CombustionSet valuenotcompileddu...

Page 89: ...estflue Theapplianceremainsinthismodeforamaximumperiodof15minutes keepingthefanspeedconstant Thefunctionendsafter15minutes orbyselecting Stop ChecktheΔPbetweenthetwopressuretestoutlets Ref 14 Fig 43 andsettheparameter Fluelength accordingtothevaluesshownin thetablesbelow VictrixZeusSuperior25 Menu Assistance Boiler Flue Pressure Min 75Pa Med 75 120Pa Max 120 210Pa Valuedetectedonfirstcheck Victrix...

Page 90: ...uto Off Boost Off alwaysoff ON alwayson Auto managed as required by the DHW Domestic hot water pro gram Setmanagement SetstheDHW Domestichotwater setcontrolmode Auto Man Man Auto the DHW Domestic hot water set will be controlled at two levels accordingtotheDHW Domestichotwater program Manual theDHW Domestichotwater setwillalwaysbefixedatthe manualvalue regardlessoftheDHW Domestichotwater program S...

Page 91: ...one1 5 C 35 C Workingmodestatus Modesetonzone1 OFF A ECO A COMF MAN Roomthermostatstatus Statusoftheroomthermostatonzone1 Open Close SetCH Thisdisplaysthezone1flowset 25 C 85 C Plant Informationrelatedtothetypeandpresenceorabsenceofaroomprobe Zone1InformationMenuisalwayspresentregardlessofwhetherornotaCARV2 isconnected notdisplayedwhenthe Req withroomprobe issettoNO displayedwhenthezoneofinteresti...

Page 92: ...s control can be disabled No or ena bledagain Yes No Yes Yes Roomsensormodul With the room probe associated it is possible to disable the modula tionontheflowtemperature No orenableitagain Yes No Yes Yes Outdoorsensormodul With the external probe present it is possible to disable the modula tion on the outdoor temperature No or enable it again Yes for the selectedzone No Yes Yes Weathercomp offset...

Page 93: ...e AddressM3 Duringtheassociation itisnecessarytoenter the concentrator acknowledgement address seedip switchonconcentrator 0 2 Status Thisdisplaystheassociationstatuswithwire lessprobe ERR Associationprocedurefailed No link Probe cannot be reached via RF in config Probe association in progress OK Probecorrectlyassociated MainMenu Pressthe MENU buttontoaccessalistofvariablesthatenableyoutocustomise...

Page 94: ...y DHWtemperature Storagetank DHW Domestichotwater outlettemperaturedisplay SetCH Thisdisplaysthesetcentralheating C H temperatureset SetDHW SetDHW Domestichotwater temperaturedisplay Externaltemperature Optional InputDHWtemperature Notusedonthismodel CHReturntemperature Returntemperaturedisplay CH2temperature Safetyflowprobedisplay Commonflowprobe Optional Dutypumpcommand Controlsignalofthepumpdut...

Page 95: ...guage seePar 2 5inthe USER chapter under Changingthe displaylanguage Incasetheuserrestoresthefactoryconditionsthrough Menu Generalsettings Userfactorysettings themenuwillappearinEng lish Proceedinthefollowingwaytorestorethedesireddisplaylanguage EnterMenu Generalsetting Language SelectthedesiredlanguagefromthoseavailableandpressOK Assistancemenuaccess MENU Generalsettings Menuaccesslevel Toactivat...

Page 96: ...onsequentrequestforcompletecalibration TheP C B definestheoperatingmodeandtheboileroutputaccordingtothecombinationofseveralparameters Thecorrectfanrevolutionstoobtainthecorrectoperatingpoweroftheappliancearedefinedfromthecombinationofparam eters Model Gastype FlueLenght thisiswhyitissuggestednottomodifythe Fanrpm parameters MENU Service Boiler Powers Menuitem Description Range Default Customised v...

Page 97: ...htherelayboard optional which canbeconfiguredonrelay2 Off relayalwaysOff Off Allarm Generalalarm CH active Central heating mode C H modeactive Gas valve External gas valve power supply Zone2 Zone2control PdC notusedonthismodel DHW active Domestic hot water mode DHWmodeactive Relay3 The boiler is set up for functioning withtherelayboard optional which canbeconfiguredonrelay3 Off relayalwaysOff Off ...

Page 98: ...edonthismodel 0 300 0seconds Waitingtimepriority Notusedonthismodel 0 100 0seconds Antilegionellastop Setsanti legionellaendtemp 0 255 180 minutes Boilerendofprecedence Notusedonthismodel MENU Service Boiler Circulator Menuitem Description Range Default Customised value Mode Sets the central heating C H pump operationmode Interm in winter mode the pump is managed according to the room controlreque...

Page 99: ... storage tank flow temperature forhysteresistype4 35 85 70 C Diff prec withhyster 4 Setthestoragetankcontrolhysteresis fortype4hysteresis 2 10 6 C DHWflowregulator Notusedonthismodel Open 8l min 10l min 12l min 14 l min 16l min Auto AutoH Auto T AutoHT Open 0 DHWminset Set minimum DHW Domestic hot water setlimitavailabletouser 10 65 10 C DHWmaxset Set maximum DHW Domestic hot water setlimitavailab...

Page 100: ...ithacommand Stop Start Functiondurationin hours Thisdisplaysthetimeremaininguntiltheendofthefunction 0 255 h Fault Thisdisplaysanycurrentanomaly MENU Service Specialfunction Chimneysweeper Menuitem Description Range Default En chimneysweeper Chimneysweepfunctionactive Stop Start Stop Status Notifiesthefunctionstatus Off On Setpowerlevel Setpowerlevel 0 100 Fanspeed Fanspeeddisplay rpm rpm CHtemper...

Page 101: ...the complete calibration function Access to the calibration window with activation of the complete calibration command makes it possibletochangethecombustionset MENU Service Specialfunction Fastcalibration Menuitem Description Range Fastcalibration Activates the quick calibration function Access to the calibration win dowwithactivationofthequickcalibrationcommand ...

Page 102: ...mum flow set during the screed heaterfunction 1 10 days 4gg Descentgradient It is possible to set the descent varia tion speed from maximum flow set to minimum flow set during the screed heaterfunction 3 30 C day 30 C g Status This displays the screed heater func tionprogress Off deactivefunction Min function active with stay time atminimumflowset Up function active with increase from minimum flow...

Page 103: ...ofashut offflue adjustingdeviceatthecouplingpointoftheflueinthepressurisedcollectiveflue itwillbenecessarytoturnoffalltheboilers connectedtothepressurisedcollectiveflueitself ormakesuretointercepttheconnectionpointtoavoidthedispersionofcom bustionproductsintotheenvironment Only then proceed to verify the components making sure that the non return valve siphon on the flue gas on the exhaust is full...

Page 104: ...omprobestatusappearsas OK Indicationsdisplayedonthe Roomprobe Status menu ThefollowingitemsappearintheRoomprobeassociationwindow Status Err configurationerror theassociationsequenceontheconcentratorwasnotsuccessful Repeattheassociationsequence Status Nolink erroronRFassociationbetweenprobeandconcentrator itmayalsoappearwithprobebatteryflat Checkwireless probeoperationandrepeattheassociationsequenc...

Page 105: ...cluded and the safety thermostat and the limit thermostat functions remain active To activate the chimneysweepfunction itisnecessarytogotothefollowingpath Menu Service Specialfunction Chimneysweeper Activatethefunctioninthefirstlinebyselecting Start This function makes it possible for the technician to check the combustion parameters in the working range that goes from minimum centralheating C H Q...

Page 106: ...n domestic hot water central heating phase the boiler is equipped with a function that starts the three waymotorisedgroup24hoursafteritwaslastinoperation runningitforafullcyclesoastoreducetheriskofthethree waygroup becomingblockedduetoprolongedinactivity 3 23 RADIATORSANTIFREEZEFUNCTION Ifthesystemreturnwaterisbelow4 C theboilerstartsupuntilreaching42 C 3 24 P C B PERIODICALSELF CHECK During funct...

Page 107: ...thecasingcanbecompletelyremovedasfollows Lowergrid Fig 64 1 Loosenthetwoscrews a 2 Removethegrid b Frontpanel Fig 65 3 Removethecovercaps c andloosenscrews d 4 Loosenthetwoscrews e securedunderthehinges 5 Pullthefrontpanel f towardsyouandreleaseitfromitslowerseat a 2 b a 1 1 2 64 a b c c 1 d 2 2 3 3 3 4 65 ...

Page 108: ...taller User Maintenance technician Technical Data Front Fig 66 6 Loosenthetwoscrews g 7 Pullthefront f slightlytowardsyou 8 Releasethefront f fromthebracket h bypushingupwardsandtowardsyou 3 3 f 2 2 1 g 1 h 66 ...

Page 109: ...ntrolpanel Fig 67 9 Loosenthefixingscrews i fromthefrontpanel 10 Tiltthecontrolpanel j towardsyou i 1 i 1 j 2 67 Sides Fig 68 11 Unscrewtheside k fasteningscrews l 12 Removethesidesbyextractingthemfromtheirrearseat Ref X l l 1 1 l 1 l 1 Rif X X X X X X X 2 2 68 ...

Page 110: ...21500 D H W 99 2 74 99 2 01 24 0 20640 93 2 63 92 1 93 23 0 19780 86 2 52 85 1 85 22 0 18920 81 2 41 79 1 77 21 0 18060 76 2 29 74 1 68 20 2 17372 HEAT D H W 73 2 20 70 1 62 19 0 16340 69 2 07 62 1 52 18 0 15480 64 1 96 59 1 44 17 0 14620 60 1 85 57 1 36 16 0 13760 57 1 74 55 1 28 15 0 12900 53 1 63 53 1 20 14 0 12040 50 1 52 51 1 12 13 0 11180 46 1 41 48 1 04 12 0 10320 44 1 30 44 0 96 11 0 9460 ...

Page 111: ...20640 55 2 60 55 1 91 23 0 19780 50 2 49 50 1 83 22 0 18920 55 2 38 47 1 74 21 0 18060 40 2 26 43 1 66 20 0 17200 38 2 15 40 1 58 19 0 16340 36 2 04 38 1 50 18 0 15480 34 1 93 36 1 42 17 0 14620 32 1 82 34 1 34 16 0 13760 30 1 71 32 1 26 15 0 12900 29 1 61 30 1 18 14 0 12040 27 1 50 29 1 10 13 0 11180 26 1 39 28 1 02 12 0 10320 25 1 29 26 0 94 11 0 9460 24 1 18 25 0 87 10 0 8600 22 1 08 23 0 79 9 ...

Page 112: ...22360 65 2 83 65 2 07 25 0 21500 60 2 71 60 1 99 24 0 20640 55 2 60 55 1 91 23 0 19780 50 2 49 50 1 83 22 0 18920 55 2 37 47 1 74 21 0 18060 40 2 26 43 1 66 20 0 17200 38 2 15 40 1 58 19 0 16340 37 2 04 38 1 50 18 0 15480 34 1 93 36 1 42 17 0 14620 32 1 82 34 1 34 16 0 13760 30 1 71 32 1 26 15 0 12900 29 1 60 30 1 18 14 0 12040 27 1 50 29 1 10 13 0 11180 26 1 39 28 1 02 12 0 10320 25 1 29 26 0 94 ...

Page 113: ...Fluetemperatureatminimumoutput C 60 53 Maxaircombustiontemperature C 50 50 Intake exhaust availableheadwith Min Intake exhaust availableheadwith Med Intake exhaust availableheadwith Max Pa Pa Pa 48 112 151 VictrixZeusSuperior30 Gastype G20 G31 Supplypressure mbar mmH2 O 20 204 31 377 Gasnozzlediameter mm 5 7 5 7 FlueflowrateatD H W nominalheatoutput kg h g s 52 14 43 50 13 86 Flueflowrateatheating...

Page 114: ...5 47 13 02 Flueflowrateatminheatoutput kg h g s 5 1 38 5 1 35 CO2 tonominalQ 8 8 0 2 10 3 0 2 CO2 toignitionQ 8 8 0 2 10 3 0 2 CO2 tominimumQ 8 8 0 2 10 3 0 2 COwith0 O2 atNom Min Q ppm 141 3 227 3 NOx with0 O2 atNom Min Q mg kWh 22 15 34 25 Fluetemperatureatnominaloutput C 44 41 Fluetemperatureatminimumoutput C 47 42 Maxaircombustiontemperature C 50 50 Intake exhaust availableheadwith Min Intake ...

Page 115: ...a Hotwaterproductionusefulheatoutput kW kcal h 25 21500 30 25800 33 8 29068 Domestichotwateradjustabletemperature C 10 60 Domestichotwatercircuitmin pressure dynamic bar MPa 0 6 0 06 Domestichotwatercircuitmax operatingpressure bar MPa 8 0 0 80 Flowratecapacityincontinuousduty T30 C l min 12 4 15 16 9 Weightoffullboiler kg 119 121 9 Weightofemptyboiler kg 63 9 64 2 Electricalconnection V Hz 230 50...

Page 116: ...ENG Md Model Cod Md Modelcode SrN SerialNumber CHK Check Cod PIN PINcode Type Typeofinstallation ref CENTR1749 Qnwmin MinimumDHWheatinput Qnmin Centralheatingminimumheatinput Qnwmax DHWmaximumheatinput Qnmax Centralheatingmaximumheatinput Pnmin Minimumheatoutput Pnmax Maximumheatoutput PMS Maximumsystempressure PMW Maximumdomestichotwaterpressure D Specificflowrate TM Maximumoperatingtemperature N...

Page 117: ...outputinhightemperature mode P4 20 2 kW Atnominalheatoutputinhightemperature mode η4 87 7 At30 ofnominalheatoutputinalow temperaturemode P1 6 9 kW At30 ofnominalheatoutputinalow temperaturemode η1 99 0 Auxiliaryelectricityconsumption Otheritems Atfullload elmax 0 021 kW Heatlossinstandby Pstby 0 058 kW Atpartialload elmin 0 015 kW Ignitionburnerenergyconsumption Pign 0 000 kW Instandbymode PSB 0 0...

Page 118: ...e η4 87 6 At30 ofnominalheatoutputinalow temperaturemode P1 9 5 kW At30 ofnominalheatoutputinalow temperaturemode η1 98 8 Auxiliaryelectricityconsumption Otheritems Atfullload elmax 0 020 kW Heatlossinstandby Pstby 0 088 kW Atpartialload elmin 0 015 kW Ignitionburnerenergyconsumption Pign 0 000 kW Instandbymode PSB 0 005 kW Emissionsofnitrogenoxides NOx 18 mg kWh Formixedcentralheatingappliances S...

Page 119: ...e η4 87 6 At30 ofnominalheatoutputinalow temperaturemode P1 9 5 kW At30 ofnominalheatoutputinalow temperaturemode η1 98 8 Auxiliaryelectricityconsumption Otheritems Atfullload elmax 0 020 kW Heatlossinstandby Pstby 0 088 kW Atpartialload elmin 0 015 kW Ignitionburnerenergyconsumption Pign 0 000 kW Instandbymode PSB 0 005 kW Emissionsofnitrogenoxides NOx 18 mg kWh Formixedcentralheatingappliances S...

Page 120: ...ZEUS SUPERIOR 25 51 dB 2019 811 2013 A A B C D E F kW A A A A B C D A A XL 20 70 Parameter value Annualenergyconsumptionforthecentralheatingmode QHE 34 7GJ Annualelectricityconsumptionforthedomestichotwaterfunction AEC 51kWh Annualfuelconsumptionforthedomestichotwaterfunction AFC 20GJ Seasonalspaceheatingenergyefficiency ηs 94 Waterheatingenergyefficiency ηwh 80 ...

Page 121: ...9 811 2013 A A B C D E F kW A A A A B C D A A XL 28 71 Parameter value Annualenergyconsumptionforthecentralheatingmode QHE 47 7GJ Annualelectricityconsumptionforthedomestichotwaterfunction AEC 53kWh Annualfuelconsumptionforthedomestichotwaterfunction AFC 19GJ Seasonalspaceheatingenergyefficiency ηs 94 Waterheatingenergyefficiency ηwh 80 ...

Page 122: ...HE 47 7GJ Annualelectricityconsumptionforthedomestichotwaterfunction AEC 54kWh Annualfuelconsumptionforthedomestichotwaterfunction AFC 19GJ Seasonalspaceheatingenergyefficiency ηs 94 Waterheatingenergyefficiency ηwh 80 Forproperinstallationoftheappliancerefertochapter1ofthisbooklet fortheinstaller andcurrentinstallationregulations Forpropermaintenancerefertochapter3ofthisbooklet forthemaintenancet...

Page 123: ...nction e g boiler solarthermalsystem Facsimileforfillinginthepackageficheforroomcentralheatingsystems Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C FFrom the board of the heat pump Temperature control From temperature control board Supplementary boiler From boiler board Supplementary heat pump From the heat pump board Solar contribution and supplementary h...

Page 124: ...at pump board Solar contribution and supplementary heat pump Select the lowest value Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C From the board of the heat pump in the distribution system and the size of the products compared to the size and features of the building Solar contribution From the board of the solar device Class I 1 Class II 2 Class III 1 5 ...

Page 125: ...lar contribution From the board of the solar device I 1 1 x I 10 x II III I Auxiliary electricity G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL in the distribution system and the size of the products compared to the size and features of the building 1 2 3 3 2 3 2 75 ...

Page 126: ...no 207 2014 Domestichotwaterproductionsystempackagefiche average climate conditions Colder 0 2 x Hotter 0 4 x Solar contribution From the board of the solar device _____ 1 1 x _____ 10 x _____ ____ ______ Auxiliary electricity G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL in the dis...

Page 127: ...127 ...

Page 128: ...bookletismade ofecologicalpaper immergas com ImmergasS p A 42041Brescello RE Italy Tel 0522 689011 Fax0522 680617 IMMERGASSPA ITALY CERTIFIEDCOMPANY UNIENISO9001 2015 Design manufactureandpost saleassistanceofgas boilers gaswaterheatersandrelatedaccessories ...

Reviews: