4.3 TECHNICAL DATA TABLE
Victrix Zeus
Superior 25
Victrix Zeus
Superior 30
Victrix Zeus
Superior 35
Domestic hot water nominal heat input
kW (kcal/h)
25.9 (22280)
30.9 (26598)
34.8 (29967)
Central heating nominal heat input
kW (kcal/h)
20.8 (17909)
29 (24976)
Minimum heat input
kW (kcal/h)
2.5 (2143)
3 (2554)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
25 (21500)
30 (25800)
33.8 (29068)
Central heating nominal heat output (useful)
kW (kcal/h)
20.2 (17372)
28.2 (24252)
Minimum heat output (useful)
kW (kcal/h)
2.3 (2012)
2.8 (2408)
*Effective thermal efficiency 80/60 Nom./Min.
%
97 / 95.4
97.1 / 94.3
*Effective thermal efficiency 50/30 Nom./Min.
%
105.1 / 105.7
105.4 / 103.7
*Effective thermal efficiency 40/30 Nom./Min.
%
107.1 / 108,8
106.8 / 108,0
Casing losses with burner On/Off (80-60°C)
%
0,38 / 1,40
0,57 / 1,40
0,51 / 1,40
Chimney losses with burner On/Off (80-60°C)
%
0,01 / 2,10
0,01 / 1,60
Central heating circuit max. operating pressure
bar (MPa)
3,0 (0,30)
Maximum heating temperature
°C
90
Adjustable central heating temperature (min. operating field)
°C
20
Adjustable central heating temperature (max operating field)
°C
85
System expansion vessel total volume
l
5.8
7.1
Expansion vessel pre-charged pressure
bar (MPa)
1,0 (0,10)
Appliance water content
l
4.7
7.3
Head available with 1000 l/h flow rate
kPa (m H
2
O)
1,03 (mca/kPa)
1,2 (mca/kPa)
Hot water production useful heat output
kW (kcal/h)
25 (21500)
30 (25800)
33.8 (29068)
Domestic hot water adjustable temperature
°C
10-60
Domestic hot water circuit min. pressure (dynamic)
bar (MPa)
0,6 (0,06)
Domestic hot water circuit max. operating pressure
bar (MPa)
8,0 (0,80)
Flow rate capacity in continuous duty (∆T 30°C)
l/min
12.4
15
16.9
Weight of full boiler
kg
119
121.9
Weight of empty boiler
kg
63.9
64.2
Electrical connection
V/Hz
230 / 50
Nominal power absorption
A
0.7
0.8
1
Installed electric power
W
95
110
130
Pump absorbed power
W
45
57
59
EEI value
-
≤ 0.20 - Det. 3
Fan power absorbed power
W
40
42
68
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
Max. flue overheating temperature
°C
120
Ambient operating temperature range
°C
0 ÷ 40
Ambient operating temperature range with optional antifreeze kit
°C
-15 ÷ 40
NO
X
class
-
6
Weighted NO
X
mg/kWh
23
21
Weighted CO
mg/kWh
15
16
**Type of appliance
-
C13-C13x-C33-C33x-C43-C43x-C53-C53x-C63-
C63x-C83-C83x-C93-C93x-C(10)3-C(12)3-C(15)3-
C(10)3x-C(12)3x-C(15)3x-B23p-B33-B53p
Category
-
II 2H3P - I 3P
* The efficiency values refer to the lower calorific value.
The data relating to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values
are measured immediately at the boiler outlet, considering that to obtain the data declared, mixing with cold water is required.
The weighted NO
x
value refer to the net calorific value.
** For type C63 it is forbidden to install the appliance as it came out of the factory, in configurations that require shared flues in positive
pressure.