1.5  REMOTE CONTROLS AND 

ROOM CHRONO-THERMOSTATS 

(OPTIONAL).

The boiler is prepared for the application of room 

chrono-thermostats or remote controls, which 

are available as optional kits.

All Immergas chrono-thermostats are connected 

with 2 wires only. Carefully read the user and 

assembly instructions contained in the accessory 

kit.

• On/Off digital chrono-thermostat (Fig. 1-4). 

The chrono-thermostat allows:

  - to set two room temperature values: one for 

day (comfort temperature) and one for night 

(lower temperature);

  - set a weekly program with four daily switch-

on/off;

  - selecting the required function mode from 

the various possible alternatives:

    - manual  operation  (with  adjustable 

temperature).

    - automatic operation (with set program).
    - forced automatic operation (temporarily 

modifying the temperature of the automatic 

program).

  The chrono-thermostat is powered by two 1.5V 

LR 6 type alkaline batteries.

• There are two types of remote controls available: 

Comando  Amico  Remoto  remote  control 

V2

  (CAR

V2

)  (Fig.  1-4)  and  Super  Comando 

Amico Remoto remote control (Super CAR) 

(Fig. 1-5) both with room chrono-thermostat 

functioning.  In  addition  to  the  functions 

described in the previous point, the chrono-

thermostat panels enable the user to control all 

the important information regarding operation 

of the appliance and the central heating system 

with the opportunity of easily intervening on 

the previously set parameters without having to 

go to the place where the appliance is installed. 

The panel is provided with self-diagnosis to 

display  any  boiler  functioning  anomalies. 

The climate chrono-thermostat incorporated 

into the remote panel enables the system flow 

temperature to be adjusted to the actual needs 

of the room being heated, in order to obtain 

the desired room temperature with extreme 

precision and therefore with evident saving in 

running costs. The chrono-thermostat is fed 

directly by the boiler by means of the same 2 

wires used for the transmission of data between 

boiler and chrono-thermostat.

Important: 

if  the  system  is  subdivided  into 

zones using the relevant kit, the CAR 

V2

 and 

the Super CAR must be used with its climate 

thermostat function disabled, i.e. it must be set 

to On/Off mode.

CAR

V2

,  Super  CAR  or  On/Off  chrono-

thermostat electrical connection (Optional)

The operations described below must be performed 

after  having  removed  the  voltage  from  the 

appliance.

 The eventual On/Off environment 

chrono-thermostat must be connected to clamps 

40 and 41 eliminating jumper X40 (Fig. 3-2). 

Make sure that the On/Off thermostat contact is 

of the “clean” type, i.e. independent of the mains 

supply, otherwise the P.C.B. would be damaged. 

Any CAR

V2

 or Super CAR must be connected 

by means of terminals IN+ and IN- to terminals 

42  and  43  on  the  circuit  board,  eliminating 

jumper X40 and respecting polarity (Fig. 3-2). 

Connection with the wrong polarity prevents 

functioning, but without damaging the Remote 

control. The boiler can only be connected to one 

remote control.

Important:

 if the Comando Remoto remote 

control is used, arrange two separate lines in 

compliance with current regulations regarding 

electrical systems. No boiler pipes must ever be 

used to earth the electric system or telephone 

lines.  Ensure  elimination  of  this  risk  before 

making the boiler electrical connections.

Installation with system operating at direct 

low temperature.

 The boiler can directly feed a 

low temperature system by acting on parameter 

“P66” (Par. 3.8) and setting the flow temperature 

adjustment range “P66/A” and “P66/B”. In this 

situation it is good practice to insert a safety 

device in series with the power supply and boiler. 

This device is made up from a thermostat with 

a temperature limit of 60°C. The thermostat 

must be positioned on the system delivery pipe 

at a distance of at least 2 metres from the boiler.

1.6  EXTERNAL TEMPERATURE PROBE 

(OPTIONAL).

The boiler is prepared for the application of the 

external probe (Fig. 1-6), which is available as 

an optional kit. Refer to the relative instruction 

sheet for positioning of the external probe. The 

probe can be connected directly to the boiler 

electrical system and allows the max. system 

flow temperature to be automatically decreased 

when  the  external  temperature  increases,  in 

order to adjust the heat supplied to the system 

according to the change in external temperature. 

The  external  probe  always  operates  when 

connected, regardless of the presence or type of 

room chrono-thermostat used and can work in 

combination with Immergas timer thermostats. 

The correlation between system flow temperature 

and external temperature is determined by the 

parameters  set  in  menu  “M5”  under  “P66” 

according  to  the  curves  represented  in  the 

diagram (Fig. 1-7). The electric connection of 

the external probe must be made on clamps 38 

and 39 on the boiler P.C.B. (Fig. 3-2).

Summary of Contents for VICTRIX Superior TOP 32 E

Page 1: ...VICTRIX Superior TOP 32 E IE Instruction and warning book 1 032471IE...

Page 2: ...DECLARES THAT the Immergas boiler model Victrix Superior TOP 32 E is in compliance with the same European Community Directives Mauro Guareschi Research Development Director Signature Dear Client Our c...

Page 3: ...r any damage caused to the household appliances It is also advisable to not position furnishings furniture etc under the boiler for the above mentioned reasons In the event of malfunctions faults or i...

Page 4: ...The instructions of the manufacturer of this liquid must be followed scrupulously regarding the percentage necessary with respect to the minimum temperature at which the system must be kept An aqueous...

Page 5: ...lime scale apparatus is preserved for example limescale deposits from the slurry formation and other noxious deposits Waterconnectionsmustbemadeinarationalway using the couplings on the boiler templa...

Page 6: ...the Super CAR must be used with its climate thermostat function disabled i e it must be set to On Off mode CARV2 Super CAR or On Off chrono thermostat electrical connection Optional The operations des...

Page 7: ...This information allows calculations to be made to verify the possibility of setting up various flue configurations Positioning of the gaskets black for green range flue extraction systems Position t...

Page 8: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust...

Page 9: ...laps Fit the male side smooth of the exhaust terminal into the the female side of the bend 90 80 making sure that the relevant wall sealing plate is already fitted this will ensure the hold and joinin...

Page 10: ...ested Horizontal intake exhaust kit 80 125 Kit assembly Fig 1 15 for the installation of kit 80 125 the flanged adapter kit must be used to be able to install the flue system 80 125 Install the flange...

Page 11: ...take exhaust pipe 5 Fit the 60 100 3 concentric terminal pipe with the male end 5 smooth into the flange 2 up to the stop making sure that the wall sealing plate has been fitted 3 this will ensure sea...

Page 12: ...flat flange present in the lateral hole with respect to the central one according to needs and replace it with the flange 3 positioning the gasket 2 already present in the boiler and tighten using th...

Page 13: ...he removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a min slope of 1 5 Assemble the lid A complete with adapter 1 and wall plugs 6 and assemble the flu...

Page 14: ...ue technical slot The max possible length of the 60 flexible ducting vertical section is equal to 30 m This length is obtained considering the complete 80 exhaust terminal 1m of 80 pipe in exhaust two...

Page 15: ...ent the circulation pump by loosening the front cap and keeping the motor running Re tighten the cap after the operation 1 19 FILLING THE CONDENSATE TRAP On first lighting of the boiler combustion pro...

Page 16: ...the power supplied by the burner greater the power greater the speed Moreover inside the parameter it is possible to regulate the operation range of the pump by setting the maximum speed adjustable fr...

Page 17: ...ly This kit is very useful for maintenance because it allows to empty just the boiler without having to empty the entire system Moreover the version with filter preserves the functioning characteristi...

Page 18: ...e of electrical power requires some fundamental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the...

Page 19: ...tral heating in order to evacuate residual flue gases F5 Postcirculation in progress Pump in function after a request for domestic hot water or central heating in order to cool the primary circuit P33...

Page 20: ...By turning the selector switch 1 in a clockwise direction the temperature increases and in an anti clockwise direction it decreases During the heating of the domestic hot water DHW ON appears on the...

Page 21: ...chnician must be called e g Immergas After Sales Service Maximum No of resets Available number of resets already made Insufficient system pressure Water pressure inside the central heating system that...

Page 22: ...in the case of malfunctioning or anomaly the display of the temperature is replaced by the relative error code present in the table Par 2 6 2 7 BOILER SHUTDOWN Switchtheboileroffbypressingthe button d...

Page 23: ...The display is always lit up OFF The display only lights up when the controls are accessed and remains on for 5 seconds after the last operation performed P32 D C P32 B D C ITALIANO D x select C All d...

Page 24: ...t by the external probe See OFFSET on the external probe graphics Fig 1 8 by modifying the temperature from 15 C to 15 C P94 D x select C It defines the flow temperature of the zone number 3 at low te...

Page 25: ...or aeration of the installation room where provided If even only a single safety check offers a negative result do not commission the system 3 1 HYDRAULIC DIAGRAM Key 1 Condensate drain trap 2 Water i...

Page 26: ...the system pressure is within established limits Check that the radiator valves are not closed and also the functionality of the pump Siphon blocked This may be caused by dirt or combustion products...

Page 27: ...board air gas circuit components or in the case of installations with fume extraction systems with horizontal concentric pipe measuring more than 1 metre The boiler heat output is correlated to the le...

Page 28: ...ive take the heating selector switch to maximum turn it in a clockwise direction until 99 is seen on the display To have an exact value of CO2 in the flue gases the technician must insert the sampling...

Page 29: ...the maximum delivery temperature With the external probe present it defines the maximum flow temperature corresponding to functioning with minimum external temperature see graphics Fig 1 8 can be set...

Page 30: ...juster on the various levels Auto automatic functioning therefore with variable flow rate Open adjuster completely open therefore maximum flow rate available 08 L M 10 L M and 12 L M ffunctioning with...

Page 31: ...t upstream from the boiler Set the P 71 function on P 71 1 Par 3 8 When the boiler inlet water is at a temperature that is equal or greater with respect to that set by the domestic hot water selector...

Page 32: ...with that indicated by the regulations in force 3 17 CASING REMOVAL To facilitate boiler maintenance the casing can be completely removed as follows disassemble the front 1 of the boiler by loosening...

Page 33: ...kg h mbar mm H2 O kg h mbar mm H2 O 32 0 27520 3 45 8 30 84 6 2 58 8 40 85 7 2 53 8 20 83 6 31 0 26660 3 34 7 80 79 6 2 49 7 88 80 4 2 45 7 76 79 2 30 0 25800 3 23 7 33 74 7 2 41 7 39 75 3 2 37 7 34...

Page 34: ...ith burner On Off 80 60 C 0 48 0 30 Heat loss at flue with burner On Off 80 60 C 0 03 2 20 Central heating circuit max operating pressure bar 3 Central heating circuit max operating temperature C 90 A...

Page 35: ......

Page 36: ...immergas com Immergas S p A 42041 Brescello RE Italy T 39 0522 689011 F 39 0522 680617 This instruction booklet is made of ecological paper Code 1 032471IE rev 15 036945 001 09 2012...

Reviews: