3.2  WIRING DIAGRAM.

Fig. 3-2

Remote controls: the boiler is designed to use 

the Comando Amico Remoto remote control

V2

 

(CAR

V2

)  or  as  an  alternative  to  the  Super 

Comando Amico Remoto remote control (Super 

CAR), which must be connected to clamps 42 

and 43 of connector X15 on the P.C.B., respecting 

polarity and eliminating jumper X40.
Room thermostat: the boiler is designed to use 

the Room Thermostat (S20). Connect it to clamps 

40 – 41 eliminating jumper X40.
The connector X5 is used for the connection to 

the relay P.C.B. 
The connector X6 is for connection to a personal 

computer.
The connector X8 is used for software updating 

operations.
The S34 selector defines the functioning of the 

boiler with the system supervisor or with the 

external probe:

S34 Off =operation with system supervisor

S34 On =operation with external probe.

3.3  TROUBLESHOOTING.

N.B.:

 maintenance interventions must be carried 

out by a qualified technician (e.g. Immergas 

After-Sales Technical Assistance Service).
- Smell of gas. Caused by leakage from gas circuit 

pipelines. Check sealing efficiency of gas intake 

circuit.

- Repeated ignition blocks. No gas, check the 

presence of pressure in the network and that 

the  gas  adduction  valve  is  open.  Incorrect 

adjustment of the gas valve, check the correct 

calibration of the gas valve.

- Irregular combustion or noisiness. This may be 

caused by: a dirty burner, incorrect combustion 

parameters,  intake-exhaust  terminal  not 

correctly installed. Clean the above components 

and ensure correct installation of the terminal, 

check correct setting of the gas valve (Off-Set 

setting) and correct percentage of CO

2

 in flue 

gases.

- Frequent  activation  of  the  temperature 

overload thermostat. It can depend on the lack 

of water in the boiler, little water circulation 

in the system or blocked pump. Check on the 

manometer that the system pressure is within 

established  limits.  Check  that  the  radiator 

valves are not closed and also the functionality 

of the pump.

- Siphon blocked. This may be caused by dirt or 

combustion products deposited inside. Check, 

by means of the condensate drain cap, that 

there are no residues of material blocking the 

flow of condensate.

- Heat exchanger blocked. This may be caused by 

the trap being blocked. Check, by means of the 

condensate drain cap, that there are no residues 

of material blocking the flow of condensate.

- Noise due to air in the system. Check opening 

of the special air vent valve cap (Part. 27 Fig. 

1-29).  Make  sure  the  system  pressure  and 

expansion vessel pre-charge values are within 

the set limits; The factory-set pressure values of 

the expansion vessel must be 1.0 bar, the value 

of system pressure must be between 1 and 1.2 

bar.

- Noise  due  to  air  inside  the  condensation 

module. Use the manual air vent valve (Part. 

13 Fig. 1-29) to eliminate any air present in the 

condensation module. When the operation has 

been performed, close the manual vent valve.

- Low circulation. The boiler leaves the factory 

calibrated with the pump set on Auto and ∆T 

between constant flow and return on 15°C. 

Check if this ∆T is correct for the system and 

if needed modify the pump settings.

 

M20  -  Fan

 

M30  -  Three-way valve

 

M40  -  D.h.w. flow-rate regulator

 

S5  -  System pressure switch

 

S20  -  Room thermostat (optional)

 

S34  -  System supervision selector 

connection 

Super CAR remote control - SUPER Comando Amico 

Remoto remote control (optional)

 

T1  -  Low voltage feeder

 

X40  -  Room thermostat jumper

 

Y1  -  Gas valve

 

1  -  Signal state

 

2  -  IMG BUS connection

 

3  -  System supervision connection

 

4  -  230Vac 50Hz power supply

 

5  -  Yellow/Green

 

6  -  Blue

 

7  -  Brown

 

8  -  White

 

9  -  Grey

 

10  -  Black

 

11  -  Red

 

12  -  Yellow

 

13  -  Green

 

14  -  Orange

 

15  -  Purple

 

16  -  Pink

 

17  -  Domestic hot water

 

18  -  Central heating

Key:

 

A4  -  Display board

 

B1  -  Flow probe

 

B2  -  Domestic hot water probe

 

B4  -  External probe (optional)

 

B5  -  Return probe

 

B6  -  Domestic hot water flow meter

 

B9  -  DHW inlet probe

 

B10  -  Flue probe

 

E1  -  Ignition electrodes

 

E2  -  Detection electrode

 

E4  -  Safety thermostat

 

E11  -  Aqua Celeris Resistance

 

E13  -  Heat exchanger safety thermofuse

 

F1  -  Phase fuse

 

G2  -  Igniter

 

M1  -  Boiler pump

Summary of Contents for VICTRIX Superior TOP 32 E

Page 1: ...VICTRIX Superior TOP 32 E IE Instruction and warning book 1 032471IE...

Page 2: ...DECLARES THAT the Immergas boiler model Victrix Superior TOP 32 E is in compliance with the same European Community Directives Mauro Guareschi Research Development Director Signature Dear Client Our c...

Page 3: ...r any damage caused to the household appliances It is also advisable to not position furnishings furniture etc under the boiler for the above mentioned reasons In the event of malfunctions faults or i...

Page 4: ...The instructions of the manufacturer of this liquid must be followed scrupulously regarding the percentage necessary with respect to the minimum temperature at which the system must be kept An aqueous...

Page 5: ...lime scale apparatus is preserved for example limescale deposits from the slurry formation and other noxious deposits Waterconnectionsmustbemadeinarationalway using the couplings on the boiler templa...

Page 6: ...the Super CAR must be used with its climate thermostat function disabled i e it must be set to On Off mode CARV2 Super CAR or On Off chrono thermostat electrical connection Optional The operations des...

Page 7: ...This information allows calculations to be made to verify the possibility of setting up various flue configurations Positioning of the gaskets black for green range flue extraction systems Position t...

Page 8: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust...

Page 9: ...laps Fit the male side smooth of the exhaust terminal into the the female side of the bend 90 80 making sure that the relevant wall sealing plate is already fitted this will ensure the hold and joinin...

Page 10: ...ested Horizontal intake exhaust kit 80 125 Kit assembly Fig 1 15 for the installation of kit 80 125 the flanged adapter kit must be used to be able to install the flue system 80 125 Install the flange...

Page 11: ...take exhaust pipe 5 Fit the 60 100 3 concentric terminal pipe with the male end 5 smooth into the flange 2 up to the stop making sure that the wall sealing plate has been fitted 3 this will ensure sea...

Page 12: ...flat flange present in the lateral hole with respect to the central one according to needs and replace it with the flange 3 positioning the gasket 2 already present in the boiler and tighten using th...

Page 13: ...he removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a min slope of 1 5 Assemble the lid A complete with adapter 1 and wall plugs 6 and assemble the flu...

Page 14: ...ue technical slot The max possible length of the 60 flexible ducting vertical section is equal to 30 m This length is obtained considering the complete 80 exhaust terminal 1m of 80 pipe in exhaust two...

Page 15: ...ent the circulation pump by loosening the front cap and keeping the motor running Re tighten the cap after the operation 1 19 FILLING THE CONDENSATE TRAP On first lighting of the boiler combustion pro...

Page 16: ...the power supplied by the burner greater the power greater the speed Moreover inside the parameter it is possible to regulate the operation range of the pump by setting the maximum speed adjustable fr...

Page 17: ...ly This kit is very useful for maintenance because it allows to empty just the boiler without having to empty the entire system Moreover the version with filter preserves the functioning characteristi...

Page 18: ...e of electrical power requires some fundamental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the...

Page 19: ...tral heating in order to evacuate residual flue gases F5 Postcirculation in progress Pump in function after a request for domestic hot water or central heating in order to cool the primary circuit P33...

Page 20: ...By turning the selector switch 1 in a clockwise direction the temperature increases and in an anti clockwise direction it decreases During the heating of the domestic hot water DHW ON appears on the...

Page 21: ...chnician must be called e g Immergas After Sales Service Maximum No of resets Available number of resets already made Insufficient system pressure Water pressure inside the central heating system that...

Page 22: ...in the case of malfunctioning or anomaly the display of the temperature is replaced by the relative error code present in the table Par 2 6 2 7 BOILER SHUTDOWN Switchtheboileroffbypressingthe button d...

Page 23: ...The display is always lit up OFF The display only lights up when the controls are accessed and remains on for 5 seconds after the last operation performed P32 D C P32 B D C ITALIANO D x select C All d...

Page 24: ...t by the external probe See OFFSET on the external probe graphics Fig 1 8 by modifying the temperature from 15 C to 15 C P94 D x select C It defines the flow temperature of the zone number 3 at low te...

Page 25: ...or aeration of the installation room where provided If even only a single safety check offers a negative result do not commission the system 3 1 HYDRAULIC DIAGRAM Key 1 Condensate drain trap 2 Water i...

Page 26: ...the system pressure is within established limits Check that the radiator valves are not closed and also the functionality of the pump Siphon blocked This may be caused by dirt or combustion products...

Page 27: ...board air gas circuit components or in the case of installations with fume extraction systems with horizontal concentric pipe measuring more than 1 metre The boiler heat output is correlated to the le...

Page 28: ...ive take the heating selector switch to maximum turn it in a clockwise direction until 99 is seen on the display To have an exact value of CO2 in the flue gases the technician must insert the sampling...

Page 29: ...the maximum delivery temperature With the external probe present it defines the maximum flow temperature corresponding to functioning with minimum external temperature see graphics Fig 1 8 can be set...

Page 30: ...juster on the various levels Auto automatic functioning therefore with variable flow rate Open adjuster completely open therefore maximum flow rate available 08 L M 10 L M and 12 L M ffunctioning with...

Page 31: ...t upstream from the boiler Set the P 71 function on P 71 1 Par 3 8 When the boiler inlet water is at a temperature that is equal or greater with respect to that set by the domestic hot water selector...

Page 32: ...with that indicated by the regulations in force 3 17 CASING REMOVAL To facilitate boiler maintenance the casing can be completely removed as follows disassemble the front 1 of the boiler by loosening...

Page 33: ...kg h mbar mm H2 O kg h mbar mm H2 O 32 0 27520 3 45 8 30 84 6 2 58 8 40 85 7 2 53 8 20 83 6 31 0 26660 3 34 7 80 79 6 2 49 7 88 80 4 2 45 7 76 79 2 30 0 25800 3 23 7 33 74 7 2 41 7 39 75 3 2 37 7 34...

Page 34: ...ith burner On Off 80 60 C 0 48 0 30 Heat loss at flue with burner On Off 80 60 C 0 03 2 20 Central heating circuit max operating pressure bar 3 Central heating circuit max operating temperature C 90 A...

Page 35: ......

Page 36: ...immergas com Immergas S p A 42041 Brescello RE Italy T 39 0522 689011 F 39 0522 680617 This instruction booklet is made of ecological paper Code 1 032471IE rev 15 036945 001 09 2012...

Reviews: