background image

C83

C43

C53

1

4

7

9

5

5

6

7

8

3

2

S

A

12 - IE

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

The kit includes:

N° 1 -  Exhaust gasket (1)

N° 1 -  Flange gasket (2)

N° 1 -  Female intake flange (3)

N° 1 -  Female exhaust flange (4)

C83

Fig. 1-23

C53

Fig. 1-22

Fig. 1-21

N° 2 -  Bend 90° Ø80 (5)

N° 1 -  Intake terminal Ø80 (6)

N° 2 -  Internal white wall sealing plates (7)

N° 1 -  External grey wall sealing plate (8)

N° 1 -  Exhaust pipe Ø80 (9)

1.12 SEPARATOR KIT INSTALLATION.

Type C configuration, sealed chamber and 

fan assisted.
Separator kit Ø80/80.

 This kit allows the air 

intake  from  outside  the  home  and  the  flue 

exhaust into a chimney or flue by means of the 

separation of the flue exhaust pipes and air intake. 

Combustion products are expelled from pipe (S) 

(in plastic, so as to resist acid condensate). Air is 

taken in through duct (A) for combustion (this 

is also in plastic). The intake pipe (A) can be 

installed either on the right or left hand side of 

the central exhaust pipe (S). Both ducts can be 

routed in any direction.
• Kit assembly (Fig. 1-21): install the flange (4) 

on the central hole of the boiler, positioning the 

gasket (1) 

(which does not require lubrication)

Position  it  with  the  circular  projections 

downwards in contact with the boiler flange 

and  tighten  using  the  hex  screws  with  flat 

end present in the kit. Remove the flat flange 

present in the lateral hole with respect to the 

central one (according to needs) and replace it 

with the flange (3), positioning the gasket (2) 

already present in the boiler and tighten using 

the supplied self-threading screws. Fit the male 

end (smooth) to the bends (5) in the female end 

of the flanges (3 and 4). Fit the intake terminal 

(6)  with  the  male  section  (smooth)  in  the 

female section of the bend (5) up to the stop, 

ensuring that the internal and external wall 

sealing plates are fitted. Fit the exhaust pipe 

(9) with the male end (smooth) to the female 

end of the bend (5) up to the stop; making sure 

that the internal wall sealing plate has been 

fitted, this will ensure sealing and joining of 

the elements making up the kit.

• Installation clearance (Fig. 1-22). The minimum 

installation clearance measurements of the 

Ø80/80 separator terminal kit have been stated 

in some limit conditions.

• Extensions  for  Ø80/80  separator  kit.  The 

maximum vertical straight length (without 

bends) that can be used or Ø80 intake and 

exhaust pipes is 41 metres, independently to 

whether they are used for intake or exhaust. 

The maximum horizontal straight length (with 

bend in suction and in exhaust) that can be 

used or Ø80 intake and exhaust pipes is 36 

metres independently to whether they are used 

for intake or exhaust.

N.B.:

 to favour the removal of possible condensate 

forming in the exhaust pipe, tilt the pipes towards 

the boilers with a min. slope of 1.5%. (Fig. 1-23).

Minimum slope 1.5 %

Summary of Contents for VICTRIX Superior TOP 32 E

Page 1: ...VICTRIX Superior TOP 32 E IE Instruction and warning book 1 032471IE...

Page 2: ...DECLARES THAT the Immergas boiler model Victrix Superior TOP 32 E is in compliance with the same European Community Directives Mauro Guareschi Research Development Director Signature Dear Client Our c...

Page 3: ...r any damage caused to the household appliances It is also advisable to not position furnishings furniture etc under the boiler for the above mentioned reasons In the event of malfunctions faults or i...

Page 4: ...The instructions of the manufacturer of this liquid must be followed scrupulously regarding the percentage necessary with respect to the minimum temperature at which the system must be kept An aqueous...

Page 5: ...lime scale apparatus is preserved for example limescale deposits from the slurry formation and other noxious deposits Waterconnectionsmustbemadeinarationalway using the couplings on the boiler templa...

Page 6: ...the Super CAR must be used with its climate thermostat function disabled i e it must be set to On Off mode CARV2 Super CAR or On Off chrono thermostat electrical connection Optional The operations des...

Page 7: ...This information allows calculations to be made to verify the possibility of setting up various flue configurations Positioning of the gaskets black for green range flue extraction systems Position t...

Page 8: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust...

Page 9: ...laps Fit the male side smooth of the exhaust terminal into the the female side of the bend 90 80 making sure that the relevant wall sealing plate is already fitted this will ensure the hold and joinin...

Page 10: ...ested Horizontal intake exhaust kit 80 125 Kit assembly Fig 1 15 for the installation of kit 80 125 the flanged adapter kit must be used to be able to install the flue system 80 125 Install the flange...

Page 11: ...take exhaust pipe 5 Fit the 60 100 3 concentric terminal pipe with the male end 5 smooth into the flange 2 up to the stop making sure that the wall sealing plate has been fitted 3 this will ensure sea...

Page 12: ...flat flange present in the lateral hole with respect to the central one according to needs and replace it with the flange 3 positioning the gasket 2 already present in the boiler and tighten using th...

Page 13: ...he removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a min slope of 1 5 Assemble the lid A complete with adapter 1 and wall plugs 6 and assemble the flu...

Page 14: ...ue technical slot The max possible length of the 60 flexible ducting vertical section is equal to 30 m This length is obtained considering the complete 80 exhaust terminal 1m of 80 pipe in exhaust two...

Page 15: ...ent the circulation pump by loosening the front cap and keeping the motor running Re tighten the cap after the operation 1 19 FILLING THE CONDENSATE TRAP On first lighting of the boiler combustion pro...

Page 16: ...the power supplied by the burner greater the power greater the speed Moreover inside the parameter it is possible to regulate the operation range of the pump by setting the maximum speed adjustable fr...

Page 17: ...ly This kit is very useful for maintenance because it allows to empty just the boiler without having to empty the entire system Moreover the version with filter preserves the functioning characteristi...

Page 18: ...e of electrical power requires some fundamental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the...

Page 19: ...tral heating in order to evacuate residual flue gases F5 Postcirculation in progress Pump in function after a request for domestic hot water or central heating in order to cool the primary circuit P33...

Page 20: ...By turning the selector switch 1 in a clockwise direction the temperature increases and in an anti clockwise direction it decreases During the heating of the domestic hot water DHW ON appears on the...

Page 21: ...chnician must be called e g Immergas After Sales Service Maximum No of resets Available number of resets already made Insufficient system pressure Water pressure inside the central heating system that...

Page 22: ...in the case of malfunctioning or anomaly the display of the temperature is replaced by the relative error code present in the table Par 2 6 2 7 BOILER SHUTDOWN Switchtheboileroffbypressingthe button d...

Page 23: ...The display is always lit up OFF The display only lights up when the controls are accessed and remains on for 5 seconds after the last operation performed P32 D C P32 B D C ITALIANO D x select C All d...

Page 24: ...t by the external probe See OFFSET on the external probe graphics Fig 1 8 by modifying the temperature from 15 C to 15 C P94 D x select C It defines the flow temperature of the zone number 3 at low te...

Page 25: ...or aeration of the installation room where provided If even only a single safety check offers a negative result do not commission the system 3 1 HYDRAULIC DIAGRAM Key 1 Condensate drain trap 2 Water i...

Page 26: ...the system pressure is within established limits Check that the radiator valves are not closed and also the functionality of the pump Siphon blocked This may be caused by dirt or combustion products...

Page 27: ...board air gas circuit components or in the case of installations with fume extraction systems with horizontal concentric pipe measuring more than 1 metre The boiler heat output is correlated to the le...

Page 28: ...ive take the heating selector switch to maximum turn it in a clockwise direction until 99 is seen on the display To have an exact value of CO2 in the flue gases the technician must insert the sampling...

Page 29: ...the maximum delivery temperature With the external probe present it defines the maximum flow temperature corresponding to functioning with minimum external temperature see graphics Fig 1 8 can be set...

Page 30: ...juster on the various levels Auto automatic functioning therefore with variable flow rate Open adjuster completely open therefore maximum flow rate available 08 L M 10 L M and 12 L M ffunctioning with...

Page 31: ...t upstream from the boiler Set the P 71 function on P 71 1 Par 3 8 When the boiler inlet water is at a temperature that is equal or greater with respect to that set by the domestic hot water selector...

Page 32: ...with that indicated by the regulations in force 3 17 CASING REMOVAL To facilitate boiler maintenance the casing can be completely removed as follows disassemble the front 1 of the boiler by loosening...

Page 33: ...kg h mbar mm H2 O kg h mbar mm H2 O 32 0 27520 3 45 8 30 84 6 2 58 8 40 85 7 2 53 8 20 83 6 31 0 26660 3 34 7 80 79 6 2 49 7 88 80 4 2 45 7 76 79 2 30 0 25800 3 23 7 33 74 7 2 41 7 39 75 3 2 37 7 34...

Page 34: ...ith burner On Off 80 60 C 0 48 0 30 Heat loss at flue with burner On Off 80 60 C 0 03 2 20 Central heating circuit max operating pressure bar 3 Central heating circuit max operating temperature C 90 A...

Page 35: ......

Page 36: ...immergas com Immergas S p A 42041 Brescello RE Italy T 39 0522 689011 F 39 0522 680617 This instruction booklet is made of ecological paper Code 1 032471IE rev 15 036945 001 09 2012...

Reviews: