38
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
N.B.
- The power data provided in the table is ob-
tained with 0.5 m long intake/exhaust pipe.
- Gas flow rates refer to heating output below a
temperature of 15°C and pressure of 1013 mbar.
- Burner pressure values refer to use of gas at
15°C.
- The number of revs for the fan on the display
is expressed in revs / 50 (Ex.: 1000 revs = 20).
3.23 VARIABLE HEAT OUTPUT.
Victrix Pro 35 1 I.
METHANE (G20)
PROPANE (G31)
HEAT OUTPUT
HEAT OUTPUT
BURNER GAS FLOW
RATE
REVS
FAN
BURNER GAS FLOW
RATE
REVS
FAN
(kW)
(kcal/h)
(m
3
/h)
(n°)
(kg/h)
(n°)
34.0
29240
3.70
5050
2.71
4900
33.0
28380
3.58
4920
2.63
4770
32.0
27520
3.47
4780
2.54
4640
31.0
26660
3.35
4650
2.46
4510
30.0
25800
3.24
4520
2.38
4380
29.0
24940
3.13
4400
2.30
4260
28.0
24080
3.02
4270
2.22
4130
27.0
23220
2.92
4140
2.14
4010
26.0
22360
2.81
4010
2.06
3880
25.0
21500
2.71
3890
1.99
3760
24.0
20640
2.60
3760
1.91
3640
23.0
19780
2.50
3640
1.83
3520
22.0
18920
2.39
3510
1.76
3400
21.0
18060
2.29
3390
1.68
3280
20.0
17200
2.19
3260
1.61
3150
19.0
16340
2.09
3130
1.53
3030
18.0
15480
1.98
3010
1.46
2910
17.0
14620
1.88
2880
1.38
2790
16.0
13760
1.78
2750
1.31
2670
15.0
12900
1.68
2630
1.23
2540
14.0
12040
1.57
2500
1.15
2420
13.0
11180
1.47
2360
1.08
2290
12.0
10320
1.37
2230
1.00
2170
11.0
9460
1.26
2100
0.92
2040
10.0
8600
1.15
1960
0.85
1910
9.0
7740
1.05
1820
0.77
1780
8.0
6880
0.94
1680
0.69
1650
7.0
6020
0.83
1540
0.61
1510
6.0
5160
0.72
1390
0.53
1370
5.0
4300
0.60
1250
0.44
1230
4.0
3440
0.49
1090
0.36
1090
3.4
2924
0.42
1000
0.31
1000