 BOILER  

INSTALLATION

1.1 INSTALLATION 

RECOMMENDATIONS.

The Mini Nike X 24 3 E boiler has been designed 

for wall mounted installation only, for heating 

environments and production of domestic hot 

water 

(when the boiler is connected to an external 

storage tank unit) 

for domestic use and similar 

purposes. 

The place of installation of the appliance and 

relative Immergas accessories must have suitable 

features (technical and structural) such to allow 

(always in safety, efficiency and comfortable 

conditions):

-  installation (according to the provisions of the 

technical legislation and technical regulations);

-  maintenance operations (including scheduled, 

periodic, routine and special maintenance);

- removal (to outdoors in the place for 

loading and transporting the appliances 

and components) as well as their eventual 

replacement with appliances and/or equivalent 

components.

The wall surface must be smooth, without any 

protrusions or recesses enabling access to the 

rear part. They are not designed to be installed 

on plinths or floors (Fig. 1-1).
Only professionally enabled companies are 

authorised to install Immergas gas appliances. 

Installation must be carried out according to 

regulation standards, current legislation and in 

compliance with local technical regulations and 

the required technical procedures.

Important

: the manufacturer declines all liability 

for damages caused by boilers removed from 

other systems or for any non-conformities of 

such equipment.
Before installing the appliance, ensure that it 

is delivered in perfect condition; if in doubt, 

contact the supplier immediately. Packing 

materials (staples, nails, plastic bags, polystyrene 

foam, etc.) constitute a hazard and must be kept 

out of the reach of children. If the appliance 

is installed inside or between cabinets, ensure 

sufficient space for normal servicing; therefore 

it is advisable to leave clearance of at least 3 

cm between the boiler casing and the vertical 

sides of the cabinet. Leave adequate space above 

the boiler for possible water and flue removal 

connections. It is just as important that the intake 

grids are not obstructed. Keep all flammable 

objects away from the appliance (paper, rags, 

plastic, polystyrene, etc.). Do not place household 

appliances underneath the boiler as they could 

be damaged if the safety valve intervenes with 

an obstructed conveying system (the safety valve 

must be conveyed away by a draining funnel), or 

if there are leaks from the hydraulic connections; 

on the contrary, the manufacturer cannot be 

held responsible for any damage caused to the 

household appliances.

For the aforementioned reasons, we recommend 

not placing furnishings, furniture, etc. under 

the boiler.

In the event of malfunctions, faults or incorrect 

operation, turn the appliance off immediately 

and contact an authorised company (e.g. 

the Technical Assistance centre, which has 

specifically trained staff and original spare 

parts). Do not attempt to modify or repair the 

appliance alone. Failure to comply with the above 

implies personal responsibility and invalidates 

the warranty.

• Installation regulations:
 - installation of these boilers in bedrooms, 

studio flats and bathrooms, or in premises 

where there are wood fired heaters (or by 

solid fuels in general) and in premises next 

to or connected to them, is subject to the 

regulatory/legislative provisions in force in 

the country.

  - Installation of gas appliances, flue exhaust 

pipes and combustion air intake pipes is 

forbidden in places with a fire risk (for 

example: garages, closed parking stalls), and 

in potentially dangerous places.

  - installation is prohibited on the vertical 

projection of cooking hobs;

  - installation is forbidden in places/rooms 

that constitute public areas of apartment 

buildings, internal stairways or other escape 

routes (e.g. floor landings, entrance halls, 

etc.).

  -  Installation is also forbidden in places/rooms 

that constitute public areas of apartment 

buildings such as cellars, entrance halls, attics, 

lofts, etc., unless otherwise provided for by 

local regulations in force.

  - type B open chamber boilers must not be 

installed in places where commercial, artisan 

or industrial activities take place, which use 

products that may develop volatile vapours 

or substances (e.g. acid vapours, glues, paints, 

solvents, combustibles, etc.), as well as dusts 

(e.g. dust deriving from the working of 

wood, coal fines, cement, etc.), which may be 

harmful for the components of the appliance 

and jeopardise operation;

  - they must also be installed in rooms where 

the temperature cannot fall below 0°C and 

must not be exposed to weathering.

1.2  MAIN DIMENSIONS.

Key:

  V  -  Electrical connection

  G  -  Gas supply

 RU  -  Cylinder unit return (optional)

 MU  -  Cylinder unit flow (optional)

  RR  -  System filling

  R  -  System return

  M  -  System flow

N.B.: connection group (optional)

Height 

(mm)

Width 

(mm)

Depth 

(mm)

785

440

240

CONNECTIONS 

GAS

WATER

SYSTEM

G

RR

R

M

3/4”

1/2”

3/4”

3/4”

Summary of Contents for 3.020857

Page 1: ...MINI NIKE X 24 3 E Instruction booklet and warning IE 1 038792ENG...

Page 2: ......

Page 3: ...ions specified in the current regulation and technical standards In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits establish...

Page 4: ...ting 11 2 7 Boiler shutdown 13 2 8 Restore central heating system pressure 13 2 9 System draining 13 2 10 Anti freeze protection 13 2 11 Case cleaning 13 2 12 Decommissioning 13 3 Boiler start up init...

Page 5: ...e intervenes with an obstructed conveying system the safety valve must be conveyed away by a draining funnel or if there are leaks from the hydraulic connections on the contrary the manufacturer canno...

Page 6: ...order to meet the system requirements es tablished by the technical regulation in force in relation to the pollution of drinking water we recommend installing the IMMERGAS anti backflow kit to be used...

Page 7: ...directly to the outside as long as the standard regulations for the flue terminal are respected as well as the existing laws Connection to chimneys or flues The connec tion of the appliances to a chim...

Page 8: ...started up even if only one of the checks should be negative 1 14 CIRCULATION PUMP The Mini Nike X 24 3 E series boilers are supplied with a built in circulation pump with 3 posi tion electric speed c...

Page 9: ...ystem filling valve 6 Flue safety thermostat 7 Flow probe 8 Primary heat exchanger 9 Safety thermostat 10 Combustion chamber 11 Ignition and detection electrodes 12 System expansion vessel 13 Burner 1...

Page 10: ...is also prohibited in the same room as suction devices or the like at the same time as the boiler unless there are additional openings dimensioned in a way to satisfy the additional requirement for a...

Page 11: ...The flow temperature can be modified by selecting the functioning curve via buttons 5 and 6 selecting a value from 0 to 9 Fig 1 5 With external probe present the relative symbol will appear on the dis...

Page 12: ...ithout having to be reset 1 20 Parasite flame This occurs in the event of a leak in the detection circuit or an anomaly in the flame control unit Press the Reset button 1 24 Push button control panel...

Page 13: ...3 bar the safety valve may be activated In this case remove water from an air vent valve of a radiator until 1 bar is reached or ask for as sistance from an authorised company In the event of frequen...

Page 14: ...ce e g a draught gauge positioned at the exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functio ning of fans ensure activati...

Page 15: ...ficiency of gas intake circuit Irregular combustion red or yellow flame When the burner is dirty or the boiler lamellar pack is blocked Clean the burner or the boiler lamellar pack Frequent interventi...

Page 16: ...boiler with storage tank 1 Lighting display Determining how to display illumination Display lighting P2 Range of values which can be set Standard setting 0 Off 1 Auto 2 On 1 Off the display is always...

Page 17: ...sure to insert the special seal rings supplied in the kit between the gas manifold and the injectors apply voltage to the appliance use the boiler push button control panel to select the gas parameter...

Page 18: ...tion phase the P C B supplies constant gas with pressure proportional to the parameter G2 set 3 10 CHIMNEY SWEEP FUNCTION When activated this function forces the boiler to variable output for 15 minut...

Page 19: ...itate boiler maintenance the casing can be completely removed as follows Fig 3 4 3 5 1 Unhook the decorative frame a from the relative lower retainers 2 Remove the decorative frame a from the casing c...

Page 20: ...20 3 5 4 4 5 6 6 d d c INSTALLATOR USER MAINTENANCE TECHNICIAN...

Page 21: ...tion time must be less than 10 seconds Visually check for water leaks or oxidation from on connections Visually check that the water safety drain valve is not blocked Check that after discharging syst...

Page 22: ...760 1 89 6 42 65 5 1 41 13 43 137 0 1 38 17 27 176 1 15 0 12900 1 77 5 70 58 1 1 32 12 00 122 4 1 30 15 43 157 3 14 0 12040 1 66 5 02 51 2 1 24 10 65 108 6 1 22 13 68 139 5 13 0 11180 1 55 4 39 44 8 1...

Page 23: ...1 20 Heat loss at flue with burner On Off 6 70 0 09 Central heating circuit max operating pressure bar 3 Central heating circuit max operating temperature C 90 Adjustable central heating temperature C...

Page 24: ...er CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum heating capacity domestic Qn min Minimum heating capacity heating Qnw max Maximum heating capacity domestic Qn m...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Reviews: