![IMKO TRIME-GW Series Manual Download Page 9](http://html1.mh-extra.com/html/imko/trime-gw-series/trime-gw-series_manual_2047649009.webp)
9
B: Configuration via SM-USB
The SONO-probe is connected via the SM-USB and the RS485-interface to a PC. With help of the software tool
SONO-CONFIG it is possible to configurate SONO-probes to an appropriate operating mode. The operating mode
depends on the application like the moisture measurement under a silo flap, inside a mixer or on a conveyor belt.
The SONO-probe can be adapted to the appropriate operating mode like cyclic measurement, averaging, filtering,
cumulating and other powerful operating parameters. Furthermore, it is possible to select a calibration curve
inside a SONO-probe with zero-offset setting. All configuration parameters are stored in a non-volatile memory
inside the SONO-probe. So the analog output (e.g. 4-20mA) of the SONO-probe which could be connected in
parallel to a PLC, responds directly to the configuration parameters.
3.2 System Setup with several TRIME-GW Line
3.3 Connection Plug and Plug Pinning
TRIME-GW Line is supplied with a 10-pole MIL flange plug.