![IMKO TRIME-GW Series Manual Download Page 27](http://html1.mh-extra.com/html/imko/trime-gw-series/trime-gw-series_manual_2047649027.webp)
27
Following possible parameter settings in mode CC inside the TRIME-GW Line can be set:
Parameter in mode CC
Function
Moisture Threshold
(in %-moisture)
Standard Setting: 1
Setting Range: 1…20
The accumulation of moisture values starts above the „Moisture Threshold“
and the analogue signal is output. The accumulation pauses if the moisture
level is below the threshold value.
No-Material-Delay
(in seconds)
Standard Setting: 5
Setting Range: 1…20
The accumulation stopps if the moisture value is below the moisture
threshold. The TRIME-GW Line starts again in a new batch with a new
accumulation after the time span of the “No-Material-Delay” is exceeded.
The last freezed summerized and averaged moisture
value is freezed at the analogue output, until the "No-
Material-Delay" time of e.g. 5 seconds has expired and
a new batch process starts.
Start of second batch process. After the period of "No-
Material-Delay" (e.g. 5 seconds) the SONO-probe reco-
gnizes, that the threshold of 1% has been exceeded.
The previously stored measurement value is cleared
and the probe starts again automatically with the con-
tinuous accumulation of measurement values (yellow
curve).
Start of first batch process. The SONO-probe recognizes
that the adjustable moisture threshold of e.g. 1% has
been exceeded and the probe starts automatically with
the continuous accumulation of measurement values
(yellow curve).
The first batch process stops. The SONO-probe recogni-
zes that the measurement value is below the moisture
threshold of 1% and the probe stops automatically with
the summation (yellow curve).
Short interruptions were bridged.