Imesa FLATWORK IRONER Installation And Use Instructions And Warnings Download Page 26

E170301x.03_EN

                                                                                                                                           29/06/2022

 

 

 

26

 

MESSAGE / EFFECT 

POSSIBLE CAUSE 

As soon as you press the START button, the machine 

starts but stops immediately, and the display remains the 

word "OFF" 

 

 
Check if: 

one  of  the  "ENGINE  THERMAL"  or  "GAS 
PRESSURE"  alarms  intervened  at  a  temperature 
below 80 ° C 

call technical support 

 
 

 

The machine works normally, without alarms, but the 

heating system does not start. 

 

 
Check if: 

the  maximum  temperature  probe  intervened:  reset  it 
manually according to the procedure described. 

if  the  machine  is  with  gas  heating,  check  that  the 
evacuation  of  the  humid  air  is  correct.  If  the 
evacuation  is  not  sufficient,  the  flame  control  unit 
remains deactivated 

call technical support 

 
 

 
 

27. 

REPORTS OF MALFUNCTION 

In the event of malfunctions, the microprocessor provides complete diagnostics.  Below is the list of alarms. However, 
the user is invited to contact, in these cases, an authorized service center for the solution of the problem occurred. 
Please note that the activation of each of the following alarms is accompanied by the intermittent and continuous sound 
of the buzzer. 

 

OVERTEMPERATURE 

The temperature of the roller has exceeded the  safe limit. If this alarm occurs, the basin opens  automatically, and the 
suction is inserted (if any). The alarm is automatically removed when the temperature falls below full scale. 
While the alarm is active, you cannot start the roller. Call Technical Support to verify the fault. 

 

FAULT PROBE 

There is a failure of the temperature probe, The behavior of the machine is the same as in case of overtemperature seen 
previously. Call the Technical Support service. 

 

THERMAL MOTOR 

There is a thermal motor signal when there is a failure of the inverter that powers the motor that drives the roller. The 
machine activates the cool down and turns on the vacuum cleaner (where present). 
Once the cool down temperature is reached, the machine turns off: the display remains the alarm that can be reset by 
turning off the machine. Call the Technical Support service. 
 

POWER ON SAFETY RESET BUTTON 

Below  the  touch  screen  is  the  SAFETY  RESET  button  of  the  safety  system.  This  system  intervenes,  illuminating  the 
button, when one of the following events occurs: 

intervention of the hand-saving bar 

opening of one of the side doors 

pressing the emergency button 

Safety is restored by pressing the SAFETY Reset button. 
If the light does not turn off, the alarm is not reset. 
It means that at least one of the elements listed above has not yet been restored, and that the machine is still on standby, 
waiting to return to safety conditions.  
 

SAFETY THERMOSTAT ACTIVATION 

It is possible that the safety thermostat has intervened. 
In this case it is necessary to rearm it. Make sure that the roller temperature is below 80°C. Turn off the machine and 
disconnect all power supplies. Open the left door and locate the safety thermostat. Unscrew the black cap and press the 
white button inside it. 
Finally, screw the black cap back on and close all the doors. 

Summary of Contents for FLATWORK IRONER

Page 1: ...E170301x 03_EN 29 06 2022 1 FLATWORK IRONER MCA INSTALLATION AND USE INSTRUCTIONS CONSERVE FOR FUTURE CONSULTATION IMESA S p A via degli Olmi 22 31040 Cessalto TV Italy ITALY...

Page 2: ...13 GAS CONNECTION TEST 19 14 KNOW THE DRYING GRILLE 19 15 WORK CYCLE 19 16 WHAT TO DO IN CASE OF ENTRAPPING 20 17 WHAT TO DO IN CASE OF LACK OF ELECTRICITY 21 18 WORK CYCLE VERIFICATION OF SAFETY SYST...

Page 3: ...ty for possible inaccuracies contained in this manual due to printing or transcription errors It reserves the right to make any changes to its products as it considers necessary or useful without prej...

Page 4: ...ore be taken the environment must be free of combustible materials support an adequate and easily accessible fire extinguisher near the machine ATTENTION Always check the correct functioning of the sa...

Page 5: ...with the machine ATTENTION ATTENTION Even when the position of the main switch is 0 the cables upstream of the switch are in voltage PSYCHOPHYSICAL CONDITION OF THE OPERATOR The operators involved in...

Page 6: ...rushing of the limbs it is absolutely forbidden to remove even temporarily the protection panels and security systems ATTENTION It is forbidden to introduce bars slats or metal objects between the iro...

Page 7: ...mise the electronic components contained within it It is recommended to check the machine upon receipt taking care to report to the carrier any damage caused during transport both to the internal comp...

Page 8: ...disassembly of any transport stops following the instructions inside the shoulders of the machine Care should be taken to store pallets and transport stops for any future movement of the machine to o...

Page 9: ...E WIDTH IRONING TABLE WIDTH mm ROLLER DIAMETER ROLLER DIAMETER mm MCA 150 1500 300 MCA 180 1800 MCA 210 2100 The models described above are intended for drying and ironing flat linen in the industrial...

Page 10: ...nvironment specifically built and used as a laundry 7 INDICATIONS ON SOUND EMISSION The airborne noise produced by the machine produces an A weighted continuous sound pressure level of less than 70 dB...

Page 11: ...f the exhaust pipe must not flow at human height and or be directed towards residential units ATTENTION Instruct the user on the danger of tampering with the exhaust pipes and or changing plugging obs...

Page 12: ...ccording to the matricular data power supply voltage frequency For supply voltages other than those envisaged request information from the manufacturer ATTENTION If the power supply comes from a diese...

Page 13: ...on can result in the ionization sensor not being detected ATTENTION The appliance must be connected to an effective ground system the manufacturer declines all responsibility in the event that this co...

Page 14: ...qualified personnel and must meet the requirements of current local and national rules and or regulations Check that the supply gas follows that indicated in the technical data plate located in the re...

Page 15: ...I SE BG EE LV LT CZ SI TR HR RONOLU PLNLES GB GR IE IT PT SKFR BEDEAT CHHU 7 5 440 C 20 22 41 G20 FR BE 18 8 350 C 20 22 89 G25 DE 11 440 D 15 22 24 G25 3 NL 11 440 D 15 22 52 G30 31 CY MT NL NO HUAL...

Page 16: ...I SE BG EE LV LT CZ SI TR HR RONOLU PLNLES GB GR IE IT PT SKFR BEDEAT CHHU 8 5 440 A 30 24 79 G20 FR BE 18 9 365 B 25 25 75 G25 DE 12 5 440 B 25 24 3 G25 3 NL 12 6 440 24 46 G30 31 CY MT NL NO HUAL BA...

Page 17: ...I SE BG EE LV LT CZ SI TR HR RONOLU PLNLES GB GR IE IT PT SKFR BEDEAT CHHU 8 480 B 25 26 8 G20 FR BE 18 6 380 B 25 26 89 G25 DE 11 480 C 20 25 86 G25 3 NL 11 1 480 C 20 26 16 G30 31 CY MT NL NO HUAL B...

Page 18: ...ned using the plastic key that is delivered with the machine documentation Access to the electrical panel must be allowed only to specialized and competent personnel With point 2 the main switch is fo...

Page 19: ...use damp sheets by passing them between roller and bands and rotating the roller by hand as described in the relevant paragraph The operation must be repeated until the temperature drops below 80 C Th...

Page 20: ...clockwise to turn the roller in the direction of ironing and extract the linen stuck At the same time insert fabrics with the usual ironing methods along the entire length of the roller to lower the t...

Page 21: ...chieve shutdown and then power removal when the stop is reached 20 START AND STOP Turn on the machine by bringing the main switch described in the earlier paragraph to the I position Make sure that th...

Page 22: ...t the choice of speed must be made by referring to the specific characteristics of the fabric The definition of speed is also related to the choice of ironing temperature IMPORTANT After the cycle has...

Page 23: ...owed by the characteristic plates of the linen to be ironed Remember that at the end of the work the machine cannot be stopped at least until the temperature has dropped below 80 C Also remember that...

Page 24: ...working hours by accessing a reserved area of the microprocessor 24 SPEED TEMPERATURE COMPENSATION You can manage the ironing machine so that the speed changes automatically as the temperature changes...

Page 25: ...oisture of the fabrics the drying temperature is too low the exhaust of the humid air is obstructed in this case the air pressure switch does not enable the ignition of the flame control unit only for...

Page 26: ...chnical Support to verify the fault FAULT PROBE There is a failure of the temperature probe The behavior of the machine is the same as in case of overtemperature seen previously Call the Technical Sup...

Page 27: ...56 Once the sequence is completed the screen with the list of menus appears on display This screen is the gateway to the user programming area Browsing it you can access the configuration of PROGRAMS...

Page 28: ...no ironing activity is in progress PEDALS allows you to manage the functionality of the pedalboard if any TEMP VEL COMPENSATION allows you to activate or deactivate the speed compensation according t...

Page 29: ...p all moving mechanical parts lubricated sprockets bearings side satellite bearings The gearbox is permanently lubricated and therefore does not require maintenance EVERY THREE MONTHS Proceed to clean...

Page 30: ...ction weaving in Nomex outwards and covering the junction in the direction of rotation of the roller Finally tension the ironing bands REPLACEMENT OF CONVEYOR BELTS IN NOMEX if necessary For the repla...

Page 31: ...collected separately from other waste The separate collection of this equipment which has reached the end of its life is organized and managed by the manufacturer The user who wants to get rid of this...

Reviews: