IMER 1106045 Operating, Maintenance, Spare Parts Manual Download Page 9

23

IMER INTERNATIONAL S.p.A.

IMER MORTAR MIXERS

If there is any risk of freezing, open the hopper plug, disconnect

the pipelines and drain all water from the circuit (fig.9).

- Before opening the drain plug or the grid, ensure

that the main switch is turned to 0 and the plug is

disconnected from the power supply.

14. MAINTENANCE

- Maintenance must be performed by adequately

trained personnel, after switching off the machine,

disconnecting it from the power supply and emptying

the hopper.

Check weekly that the compressor air filter is clean. If

deteriorated, replace.

Check weekly that the electric motors are free of dust and dirt

and if necessary clean using compressed air.

Check weekly that the plug and socket contacts are clean, dry

and rust free.

Every six months arrange for an inspection of the machine by

an authorised IMER service centre.

- Spent oil is a special waste. Therefore it must be

disposed of according to current legislation.

- Always keep notices and symbols on the machine

legible.

15. REPAIRS

- Never start up the mortar mixer during repairs.

Repairs to the electrical installation must be performed

exclusively by specialised personnel.

Use exclusively original IMER spare parts; modifications

to parts are strictly prohibited.

- If any guards are removed for repairs, ensure they

are refitted correctly at the end of work.

 FIG.9

Summary of Contents for 1106045

Page 1: ...fax 0577 983304 INTONACATRICE GUNITEUSE MORTAR MIXER VERPUTZMASCHINE ENFOSCADORA 1106045 Manuale uso manutenzione ricambi Manuel utilisation entretien pi ces de rechange Operating maintenance spare p...

Page 2: ...ANIVELLE 4b ROULEAU 5 GRILLE TREMIE 6 TREMIE 7 TABLEAU ELECTRIQUE 8 MOTOREDUCTEUR 9 AGITATEUR 10 ROTOR VIS EXCENTRIQUE 11 STATOR VIS EXCENTRIQUE 12 TUBE SORTIE MATERIAU 13 FIXATION A CAMES 14 CAPTEUR...

Page 3: ...0 8 14 PRESSIONE MASSIMA PRESSIONMAXIMUM MAXIMUM PRESSURE HH CHSTDRUCK PRESI N M XIMA bar 15 MASSIMA DISTANZA DI POMPAGGIO TUBO DIAM 19MM TUBO DIAM 25MM DISTANCEDEPOMPAGEMAXIMUM TUBE DIAM 19MM TUBE DI...

Page 4: ...s in this manual carefully This OPERATION AND MAINTENANCE manual must be kept by the Site Manager and be always available for consultation The manual is considered part of the machine and must be stor...

Page 5: ...of application In general the greater the air flow rate the finer the material spray delivered The 180 l min compressor is suitable for most products which after spraying on walls require manual distr...

Page 6: ...t surface or slightly inclined towards the material outlet Route machine pipelines as required by the product application avoid excessive bends or kinks on the hoses If pipelines are routed upwards se...

Page 7: ...ote control the pump starts to rotate slowly Depending on the machine configuration wait until the grout in the hopper reaches the level of the mixer or until the coloured product is delivered from th...

Page 8: ...eline couplings checking previously if any residual pressure is present The material pressure gauge must indicate 0 bar and the pipelines excluding the clogged sections must be flexible The personnel...

Page 9: ...weekly that the electric motors are free of dust and dirt and if necessary clean using compressed air Check weekly that the plug and socket contacts are clean dry and rust free Every six months arrang...

Page 10: ...density of the material equal to that of a plastering mortar by adding water Work with lower flow rates Material flow to the gun stops A red light illuminates on the electrical panel ERR00 ERR04 Clog...

Page 11: ......

Reviews: