Global Setup Menu Functions
58
VTM-2000 Installation and Operation Handbook
PAL Waveform Scale
The PAL Waveform scale menu is used to select the unit of measurement for the PAL
Waveform. The selections are Volts or Units. The default selection for the PAL Waveform
menu is UNITS.
DC Restore
DC Restore is used to remove the DC voltage of the analog signal in order to maintain a DC
level on the waveform. The DC Restore selections are Off and On (slow).
Off = DC offset appears.
On Slow = DC offset removed.
Waveform Intensity
The Waveform Intensity is used to raise or lower the brightness of the displayed waveform.
The range of intensity is 25% to 200%. NORMAL is the default intensity setting.
Waveform Contrast
Waveform Contrast is used to adjust the overall difference between the lightest and darkest
colors of the waveform. The range of contrast is 25% to 200%. NORMAL (100%) is the default
contrast setting.
Persistence
Persistence is used to determine how long a data point (pixel) in the waveform remains on
the display. The ranges of Persistence is NORMAL, 1 TO 6, and INFINITE. NORMAL is the
default setting.
Attack
Attack is the initial intensity that the data point (pixel) appears in the display. The range of
attack is LOW, 2 to 6, and MAX. LOW is the default setting.
Vector Setup Menu
The Vector Setup menu is used to select the PAL Overlay, SDI I/Q Lines, Vector Intensity,
Vector Contrast, Persistence, and Attack.