12
HOMS
+
OP
+
and OHDS
+
OP
+
Installation and Operation Manual
Chapter 2: Installation
Maximum Frame Power Ratings
HOMS
+
OP
+
and OHDS
+
OP
+
modules operate only in fan cooled
FR6802
+
frames, subject to the limitations shown in
Table 2-1
. These
modules cannot be installed in 6800/7000 series frames.
CAUTION
To maintain proper temperatures, ensure that the front panel is
closed at all times, and that the fan module is fully operational.
Table 2-1.
Frame Power Ratings
6800
+
Frame
Type
Power
Supply
Max. Frame
Power
Dissipation
Number
of Usable
Slots
*
Max. Power
Dissipation
Per Slot
HOMS
+
OP
+
and
OHDS
+
OP
+
Requirements
FR6802
+
XF
AC
120 W
20
6 W
• 6W
(HOMS
+
OP
+
xx4D
and
OHDS
+
OP
+
xx4D)
• 12 W
(HOMS
+
OP
+
xx8D
and
OHDS
+
OP
+
xx8D)
FR6802
+
XF48
DC
105 W
20
5.25 W
FR6802
+
QXF AC
or
DC
120 W
20
6 W
* Each front module requires two of these slots. Therefore, to calculate the maximum power dissipation
available per module, double the rating shown in the Max. Power Dissipation Per Slot column.